![Jetmaster INSET STOVE MKIII 60i Скачать руководство пользователя страница 9](http://html2.mh-extra.com/html/jetmaster/inset-stove-mkiii-60i/inset-stove-mkiii-60i_user-manual_3835265009.webp)
Installation & Operation manual of Jetmaster UK clean burn range
Page 9
Revision 10/02/2010
APPLIANCE PREPORATION
Door Removal
Unlock the door with the handle provided.
Open the door fully and carefully support the door, at the same time pull out the top and bottom hinge pins.
Lift the door outwards away from the hinge attachments on the inner firebox. Set aside the hinge pins in a
safe place for refitting later.
Take care not to damage the door seal.
Place the door on a soft surface in a safe position to protect the glass, paint and inner seal.
Particular attention should be given so that the painted edges do not become damaged.
Refit the door using the reverse process.
Tertiary Air Tube Removal and V Board Baffle Removal
There are two tertiary air tubes located at the top of the inner firebox to bring air into the fire. One is large and one
is small. Each tube is held in its position by a swing cam catch attached with a single 8mm bolt to the right hand
inner side of the firebox. The cam catch has a locator at its end that locates in a hole at the end of the tube. When
the cam catch locator is positioned in the tube hole the bolt is tightened to hold it in this position thus trapping the
tube. This ensures that the tube will not slide out and it keeps the tube with its tertiary air ports in the correct
position within the fire.
Above the two tubes are three V board baffles. The two lower baffles are loose, just resting on the tubes and
touching the rear of the inner firebox. They are not fixed with any fixings. The one upper V board baffle is held in
place by a bracket that is fixed at the front top of the inner firebox.