85
12.2
Forceteq® basic via Realtime Bus
The force values are transmitted as process data
objects (PDO) cyclically according to the bus cycle time
12.2.1
CANopen over Ethernet
Parameter
Objekt (PDO)
Description
Position Actual [Inc]
6064h
Position actual
I_Force Actual [mA]
2005h
Force-equivalent current actual
Limit I_Force [x10mA]
6073h
Limitation of force-equivalent current
Process Status Register
2006h Bit 15
Limitation of force-equivalent current
reached
12.2.2
Ethernet/IP
Parameter
Class
Instanz
Id
Description
PositionActual [Inc]
0x66
0x1
0x24
Position actual
IForceActual [mA]
0x64
0x1
0x5
Force-equivalent current actual
LimitIForce [x10mA]
0x66
0x1
0x33
Limitation of force-equivalent current
ProcessStatusRegister
0x64
0x1
0x6 Bit15
Limitation of force-equivalent current
reached
12.2.3
Profinet
Parameter
PROFIdrive
Telegram 9
I/O Data
Number
Description
XIST_A [Inc]
Standard
4&5
Position actual
I_Force Actual [mA]
Supplementary
Data 4
Data 5
2&3
1&2
Force-equivalent current actual
Limit I_Force [x10mA]
Supplementary
Data 4
Data 5
1
1
Limitation of force-equivalent current
Process Status Register
Supplementary
Data 4
Data 5
6&7 Bit 15
5&6 Bit 15
Limitation of force-equivalent current
reached