Chapter 8
Measure Mode – Basic Tab
FDR
DSAM Help User Guide
Rev. 001
181
2
Connect the LST-1700 to the DSAM using one of the following
cables:
–
Part Number 1217-00-0251C
(for DSAM with standard
battery)
–
Part Number 21103805
(for DSAM with high capacity battery)
3
Apply power to
both devices
.
4
Press
Measure
.
5
Press the
Basic
softkey.
6
Using the arrow keys, select
FDR
.
7
Press
ENTER
.
8
Using the arrow keys, position the
distance marker
over a reflec-
tion to pinpoint its distance and amplitude. (The corresponding
information is displayed directly below the graph.)
Understanding
FDR Results
The FDR graphs distance on the X-axis and amplitude on the Y-axis
as the LST-1700 transmits signals down the cable and looks for RF
energy being reflected back. Reflections occur when there is a change
in impedance possibly caused by such things as cable damage, un-
terminated ports, or improper installation.
Figure 165
Measure Mode – Basic Tab: FDR
N
NOTE
To save the results to a file, refer to
.