Chapter 5
Configuring the Meter
Configure – Measure Tab
DSAM Help User Guide
Rev. 001
69
Return QAM
Generator
Use the Return QAM Generator screen to select or define the best
measurement parameters for your current work practices.
Configuring Return
QAM Generator
To configure Return QAM Generator
1
Press
Configure
.
2
Press the
Measure
softkey.
3
Using the arrow keys, select
Return QAM Generator
.
4
Press
ENTER
.
Table 26
VoIPCheck Parameters
Name
Description
Server IP
Address
The numerical identification (logical address)
assigned to the server that identifies it to the net-
work. The valid range for this value is 0.0.0.0 to
255.255.255.255. All IP addresses are numeric
only.
Ethernet Port of
the Server
The 4-digit port number on the Ethernet server.
Codec to Simu-
late
The ID of the device used to convert analog signals
to digital signals. The default option is G.711u.
Size (ms) of the
Jitter Buffer
Size (or time in ms) to be used to buffer temporary
effects caused by instability in transmission. The
default value is 40.
Figure 59
Configure – Measure Tab: Return QAM
Generator