DMX MODE - setting the operation mode

The P12 Wash has 2 operating modes (see channel assignment page 21). All parameters of 
P12 Wash can be operated via mode 1. However, all channels (except pan/tilt) are controlled with 
8 bits. By selecting Mode 2 - 16 Bit the gobo, prism rotation, CMY/CTO, dimmer, focus, zoom, 
the complete shutter slide unit as well as pan/tilt are controlled via 16 Bit.

CAMERA MODE - setting the repetition frequency of the LEDs

To avoid flickering during TV recordings, the P12 Wash can be adjusted from 50 Hertz (PAL, 
Secam) to 60 Hertz (NTSC) for different camera systems. Flex mode is set when using different 
camera systems or when shooting with mobile phone cameras or similar non-professional 
cameras. A  HighFlex mode is also available. In this mode, the repetition frequencies are set 
to 3 kHz, which is necessary to ensure smooth movements in dimmed lighting scenes. The 
factory setting of the P12 Wash is 60 Hertz. The changeover is also possible with the light mixing 
console via the control channel.

CURVES - setting dimmer, RGB/CMY, frost curve

Dimmer curve:
The dimmer curve can be changed from exponential (square) to linear. The “exponential” dimmer 
curve (factory setting) causes the dimmer to fade in and out more smoothly.
RGB/CMY curve:
3 different curves can be set for the RGB / CMY curve. SQUARE INV. LEGACY is the original 
curve of the P12. The SQUARE-INV.LEGACY curve causes a visually more uniform retraction. 
LINEAR and SQUARE INV., Are the two adapted curves on the P18 MK2.
Frost curve:
The frost curves can be changed from invers exponential (square inv.) to linear. The “invers 
exponential” frost curve causes the frost to fade in and out more smoothly.

COOLING MODE - adjustment of brightness and fan volume

In the COOLING MODE menu item you can set the fan control and the brightness of the P12 
Wash. The following settings are available.
THEATRE WHISPER: Brightness 19000lm, volume 29dB(a). In this mode, the spotlight runs at 
the same brightness up to an ambient temperature of 40°C. It is not necessary to speed up the 
fans in this mode.
THEATRE SILENT: Brightness 21000lm, from 40°C ambient temperature the spotlight regulates 
the fans a little up thus remains that the brightness is always the same level.
STANDARD: Brightness 23000lm, from an ambient temperature of approx. 36°C the fans run to 
cool the LED accordingly. The brightness remains constant.
BOOST: Brightness 25000lm, the fans run a little stronger in this mode, from approx. 40° ambient 
temperature the fans run again accordingly.
LONGLIFE: Brightness 21000lm, the fans run a little stronger in this mode, from approx. 40° 
ambient temperature the fans run again accordingly. We would recommend this mode for per-
manent installations, as the LED module runs cooler and thus more “stress-free”.
There is no danger to the life of the device in any mode, as the P12 Wash has a temperature safe-
ty shutdown. In addition, the LED module is switched off from an ambient temperature of 60°C!

DMX OUTPUT CONFIG - configuration of the DMX output

Under this menu item, the DMX output of the headlamp can be activated, that is a received Art-
net, or wireless DMX signal can be output by activating this menu item -> ON via the DMX socket 
again. Make sure that there is no signal at the DMX input at the same time !!

Under IP ADDRESS -> DEFAULT IP this can be changed from the network 10.xxx.xxx.xxx to a 
network 2.xxx.xxx.xxx. For your own self-definable IP address, you can set your own desired IP 
address under IP ADDRESS -> USER-IP. This address is divided into BYTE1 to BYTE 4 and can 
be set one after the other.

Содержание P 12

Страница 1: ...Operating instructions Version 1 03 Software 1 1 0 P1 2 Wash...

Страница 2: ...02 P1 2 Wash...

Страница 3: ...ng 16 5 5 PERSONALITY Personal settings 16 5 6 STANDALONE operation 19 5 7 INFO menu 20 5 8 Shortcuts quick access 20 6 Control options 21 6 1 DMX 21 6 1 Operating modes 21 6 1 2 DMX channel assignmen...

Страница 4: ...be Oberfl che Lichtanlagentechnik GmbH Sallersteig 15 89134 Blaustein 264 421 140 140 223 65 433 479 231 Name Erstellt Art Nr Datum Fax 07304 9617 99 Tel 07304 9617 0 P1 14 02 2019 Kuehngruen Allgemei...

Страница 5: ...TRUE1 Input Bottom cover Top cover Arm cover Handles LCD display Function keys e Material e Abmessung Name Erstellt Art Nr Datum Prisma Fax 07304 9617 99 Tel 07304 9617 0 P12 14 02 2019 Kuehngruen Al...

Страница 6: ...s as this could result in fire or electric shock Do not place any objects on the power cable Do not install the spotlight in such a way that people can trip over or step on the power cable Make sure t...

Страница 7: ...device Avoid brute force during installation or operation This light was designed for indoor use only Do not expose this device to rain or moisture When choosing a mounting location make sure that the...

Страница 8: ...sifthedeviceistobetransported When using the original packaging the locks must not be closed ATTENTION Only have plugs installed by a specialist The P12 Wash spotlight is supplied with a partially ass...

Страница 9: ...ti vated or a DMX signal is present Connection outside Europe The P12 Wash may only be operated on the following power supply systems Mains P12 Wash 2 wires 1 phase L N L N PE 3 wires 1 phase L N L L...

Страница 10: ...abling Ethernet cabling can be done with standard network lines The sockets on the device are Neutrik etherCON sockets Special cables with etherCON connectors are recommended by Neutrik The two socket...

Страница 11: ...the unit on the floor make sure that it stands on rigid ground because the air inlets in the base must not be covered with anything 140 223 65 140 1 2 4 3 To mount the unit on a trussing system use tw...

Страница 12: ...dule ENTER calls up a sub menu or confirms an input ESC is used to exit a function or a menu item UP and DOWN are used to navigate within the menu and to enter values Special areas can only be called...

Страница 13: ...ion shows an error in the ERROR LIST is still in it but has already been confirmed or was automatically confirmed Only when the error has been deleted from the ERROR LIST does the P12 Wash start again...

Страница 14: ...ONGLIFE THEATRE WHISPER THEATRE SILENT FLEX FAST DMX ADDRESS ADDRESS ARTNET ADDRESS DMX MODE MODE 1 MODE 2 ON OFF DEFAULT IP NETWORK 10 NETWORK 2 USER IP BYTE 1 BYTE 2 BYTE 3 BYTE 4 ADDRESS ADDRESS AD...

Страница 15: ...ARKLE SPARKLE SP FROST FROST 2 MACRO SPEED P T SPEED EFF MOVE B OUT YELLOW CTO SPARKLE SPARKLE SP FROST FROST 2 MACRO SPEED P T SPEED EFF MOVE B OUT AUTOFOCUS DIS AUTOFO DIS AUTOFOCUS ADJ AUTOFO ADJ C...

Страница 16: ...N buttons The Artnet address is displayed in the form 000 00 00 This display corresponds to Net Subnet Universum The sACN address can then be selected in the DMX NET ADDR sACN ADDRESS menu The address...

Страница 17: ...OLING MODE adjustment of brightness and fan volume In the COOLING MODE menu item you can set the fan control and the brightness of the P12 Wash The following settings are available THEATRE WHISPER Bri...

Страница 18: ...celeration and deceleration ramp effects are set to maximum speed Very fast gobo and color changes are possible BACKLIGHT MODE setting the display backlight This menu item controls the backlight of th...

Страница 19: ...and position and determine the individual sequence times of the steps with FADE TIME and NEXT TIME time for the complete step Use INSERT to insert an additional programming step The DMX values of the...

Страница 20: ...portant source of internal information Under the menu item TOT OPERATE TIME the complete operating time of the headlight is displayed The menu item TOT LAMP TIME provides information about the pure op...

Страница 21: ...is fine Channel 17 Aperture 2a Gobo 1 Channel 18 Aperture 2b Gobo 1 rotation Channel 19 Aperture 3a Gobo 1 rotation fine Channel 20 Aperture 3b Aperture 1a Channel 21 Aperture 4a Aperture 1a fine Chan...

Страница 22: ...hannel 43 Magenta fine Channel 44 Yellow Channel 45 Yellow fine Channel 46 CTO Channel 47 CTO fine Channel 48 Sparkle Channel 49 Sparkle speed Channel 50 Frost 1 Channel 51 Frost 2 Channel 52 Pan tilt...

Страница 23: ...w not used Setting for minimum medium DMX smoothing Dimmer fade out via fader fast slow not used Setting for medium DMX smoothing Dimmer fade out via fader fast slow not used Setting for medium maximu...

Страница 24: ...IUM FAST LED FADE OUT MODE selection of dimming out STANDARD SOFT not used COOLING MODE Adjust the fan volume and brightness This takes place with dimmer shutter set to closed DMX 000 then after 2 sec...

Страница 25: ...rapid slow Shutter open 000 015 016 095 096 110 111 111 112 125 126 126 127 126 128 142 143 143 144 158 159 159 160 174 175 175 176 190 191 191 192 206 207 207 208 222 223 223 224 238 239 239 240 254...

Страница 26: ...224 255 14 18 Gobo positioning rotation Gobo positioning 0 540 Gobo rotation right rapid slow Stop gobo rotation Gobo rotation left slow rapid 000 191 192 222 223 224 225 255 19 Gobo positioning rota...

Страница 27: ...RI P12 Wash HP CTB 7000K P12 Wash HC HCRI White P12 Wash HP CTB White 7000K P12 Wash HC Linear colours White Red Yellow Magenta Green Orange Dark Blue Pink HCRI CTB White Colour cycle right rapid slow...

Страница 28: ...ed sparkle effect slow rapid Repetition of the fading and switching blocks 000 031 032 063 064 255 32 50 Frost 1 Frost 0 100 000 255 33 51 Frost 2 Frost 0 100 000 255 34 52 Pan tilt speed Real time mo...

Страница 29: ...nge from software version 1 5 6 1 5 Zoom auto focus distance auto focus balancing 6 2 Artnet The spotlight can be controlled via Artnet ArtNET 4 To do this set the Artnet address via the menu item DMX...

Страница 30: ...and receive it via Artnet The RDM functionality depends on the lighting control desk used the operating instructions of the respective desk manufacturer must also be observed Every P12 has a factory...

Страница 31: ...On Off Dimmer Curve RGB Curve Frost Curve Camera Mode Cooling Mode Pan Tilt Speed Effect Speed Backlight Mode Disp Orientation Main Screen Mode Safe Mode Switch LED Fade Out Mode 6 5 4 Manufacturer sp...

Страница 32: ...tion keys to select the DMX channel to be tested The display shows the incoming value at the same time the P12 Wash reacts ac cordingly INIT PAN TILT The P12 Wash is calibrated in the pan tilt positio...

Страница 33: ...insert of the P12 Wash WARNING Disconnect fixture before opening 1 1 2 2 3 3 5 To change the rotating gobos remove only the clamping ring A with a pointed object replace the gobo and then put the clam...

Страница 34: ...regular intervals Above all make sure that the air intakes and the interior of the P12 Wash are free of fluff and dust To do this open the head cover 4x camlocks with half a turn and the base plate o...

Страница 35: ...ide rails and the rotating gobos should be checked for sufficient lubrication at regular intervals once a year To do this open the head cover 4x cam locks with half a turn the zoom cover 3 Phillips sc...

Страница 36: ...ity HC 19000 Lumen 20 C Luminous intensity WW 17000 Lumen 20 C Effects Pan 546 74 Tilt 281 16 Zoom 11 66 Construction Colour black Housing PC ABS Protection class IP 20 Plug in technology yes Installa...

Страница 37: ...methods Limit value class A Radiation Information technology equipment radio interference characteristics EN 55022 2010 Limit values and measuring methods Limit value class A Harmonic currents Electr...

Страница 38: ...38 P1 2 Wash...

Страница 39: ...39 P1 2 Wash...

Страница 40: ...JB Lighting Lichtanlagentechnik GmbH Sallersteig 15 89134 Blaustein Tel 49 7304 9617 0 Fax 49 7304 9617 99 info jb lighting de www jb lighting de...

Отзывы: