119
P
LUMBING
S
YSTEM
7. After the recommended amount of sanitizing solution is in the tank; the water tank
LVIXOOWKHFDUWULGJHZDWHU¿OWHULIVRHTXLSSHGLVE\SDVVHGRUWKH¿OWHULVUHPRYHG
IURPWHUZDWHU¿OSRZHUWRZDWHUKHDWHUVKRXOGEH2))ERWKVZLWFKHVHOHFWULF /3
gas). When the fresh water tank is full; set the valves
to the
DRY CAMPING
setting. Turn the pump ON and
VDQLWL]HGZDWHUZLOOÀRZLQWRWKHZDWHUOLQHVIURPWKHWDQN
8.
Open all hot water faucets one by one until water begins to
ÀRZFRQWLQXRXVO\DQGDFKORULQHVPHOOLVQRWLFHDEOH,QFOXGHRXWVLGHVKRZHUIDXFHWVLI
so equipped). Close hot water faucets.
9.
2SHQDOOFROGZDWHUIDXFHWVRQHE\RQHXQWLOZDWHUEHJLQVWRÀRZFRQWLQXRXVO\DQG\RX
smell chlorine. Include the outside shower faucets (if so equipped). Close cold water
faucets.
10. Turn OFF the water pump.
11. Let the solution remain in the tank and lines for at least four hours when disinfecting
with 50-PPM residual chlorine. If a shorter time period is desired, then a 100-PPM
chlorine concentration should be permitted to sit in the system for at least one hour.
12. After the required period, drain the chlorine solution from the fresh water system (see
Draining the Fresh Water System)
.
Rinse the system with fresh water:
13. Fill the fresh water tank full of clean (potable) water. Use water from either a pressurized
source, or from a container (as detailed below).
a.
Filling from a pressurized source:
Set the valves to the
POWER FILL TANK
setting. Connect a non-toxic drinking hose to the city water connection inlet.
Connect the other end of the hose to the pressurized water source. Turn on the
water source. When tank is full, turn off the water
VRXUFHGLVFRQQHFWWKHKRVHIURPWKHZDWHUVRXUFH¿UVW
then disconnect from the utility panel.
b.
6\SKRQ¿OOLQJIURPDZDWHUFRQWDLQHU
: Set the valves to the
SANITIZE
setting.
Insert a hose into the city water connection inlet; place the other end of the hose in
a container of water. Turn the pump ON to draw water into the tank. After the tank
is full, turn the pump OFF. Remove the hose and the container. To aid in siphoning
place the container on a surface approximately (2) feet
off the ground. Drain valves must be off.
NOTE:
To thoroughly sanitize the fresh water tank, the unit should
be driven around for a period of time allowing the solution to splash
the sides and top of the tank
Table of Contents
Table of Contents
Maintenance Record
Maintenance Record
Содержание PINNACLE
Страница 1: ...2016 CAMPING TRAILERS PRINTED ON RECYCLED PAPER 0210677 2016 2016 PINNACLE TOWABLES...
Страница 2: ...B...
Страница 4: ......
Страница 10: ......
Страница 12: ...2...
Страница 70: ...60 VEHICLE OPERATION Notes...
Страница 82: ...72 ELECTRICAL SYSTEM Notes...
Страница 110: ...100 FUEL PROPANE SYSTEM Notes...
Страница 144: ...134 PLUMBING SYSTEM Notes...
Страница 148: ...138 HEATING COOLING Notes...
Страница 164: ...154 ELECTRONICS...
Страница 176: ...166 EXTERIOR Notes...
Страница 184: ...174 ADDITIONAL INFORMATION Notes...
Страница 185: ...175 ADDITIONAL INFORMATION Notes Table of Contents Table of Contents Maintenance Record Maintenance Record...
Страница 187: ...177 ADDITIONAL INFORMATION Notes Table of Contents Table of Contents Maintenance Record Maintenance Record...