118
P
LUMBING
S
YSTEM
S
ANITIZING
THE
P
LUMBING
S
YSTEM
When to sanitize:
When your RV is new.
At the beginning and end of each season.
When the water system becomes contaminated or every three months of use.
How to Sanitize
1.
Turn water heater power OFF. Both switches:
(
electric & LP gas).
Set the valves to
SANITIZE
as indicated on the
utility center label. (Setting these valves bypasses the
water heater automatically.)
2.
Level the recreation vehicle and drain the fresh water system. (see
Draining the Fresh
Water System).
3.
Close the low point drain valves and the fresh water tank drain valve.
)XOO 6\VWHP &DQLVWHU ZDWHU ¿OWHU LI VR HTXLSSHG
Remove the canister; take the
¿OWHURXWRIWKHFDQLVWHUWKHQUHDWWDFKWKHHPSW\FDQLVWHU
%\SDVVWKHFDUWULGJHZDWHU¿OWHULIHTXLSSHG
Use the clear plastic tube (supplied
ZLWK59WRE\SDVVWKHZDWHU¿OWHU
4.
Prepare a chlorine solution using 1/4 cup of household bleach (sodium hypochlorite
solution) to one gallon (3.785 liters) of water in a container. Prepare one gallon of
solution for every 15 gallons of tank capacity. This will result in a residual chlorine
concentration of 50 ppm in the water system.
If a 100-ppm concentration is required as discussed in step 12, use ½ cup of household
bleach with one gallon of water to prepare the chlorine solution. One gallon of the
solution should be used for each 15 gallons of tank capacity.
5. Put the sanitizer solution in the fresh water tank; attach a hose to the city water
connection inlet. Insert the other end of the hose into a container holding the chlorine
solution.
Do not
use your non-toxic drinking water hose.
Turn the pump switch
ON. The solution will be drawn into the fresh water tank. Turn the pump OFF when
solution has been drawn into the tank. To aid in siphoning, set the container on a surface
approximately (2) feet off the ground. The drain valves must be turned OFF.
6.
5HPRYHWKHFKORULQHFRQWDLQHUDQG¿QLVK¿OOLQJWKHIUHVKZDWHUWDQNZLWKFOHDQSRWDEOH
water until the tank is full. Keep the valves set on
SANITIZE
.
Leave the hose attached
to the city water connection inlet; place other end of hose in a container of fresh water.
Turn the pump ON. Fresh water will be siphoned into the tank. Turn pump OFF when
tank is full. Disconnect the hose from
utility center.
NOTE:
Fresh water tank sizes vary by model, please contact your
GHDOHURU&XVWRPHU6HUYLFHIRU\RXUVSHFL¿FWDQNVL]H
Refer to Uni-Dock Utility Center for setting details
and color key
Содержание PINNACLE
Страница 1: ...2016 CAMPING TRAILERS PRINTED ON RECYCLED PAPER 0210677 2016 2016 PINNACLE TOWABLES...
Страница 2: ...B...
Страница 4: ......
Страница 10: ......
Страница 12: ...2...
Страница 70: ...60 VEHICLE OPERATION Notes...
Страница 82: ...72 ELECTRICAL SYSTEM Notes...
Страница 110: ...100 FUEL PROPANE SYSTEM Notes...
Страница 144: ...134 PLUMBING SYSTEM Notes...
Страница 148: ...138 HEATING COOLING Notes...
Страница 164: ...154 ELECTRONICS...
Страница 176: ...166 EXTERIOR Notes...
Страница 184: ...174 ADDITIONAL INFORMATION Notes...
Страница 185: ...175 ADDITIONAL INFORMATION Notes Table of Contents Table of Contents Maintenance Record Maintenance Record...
Страница 187: ...177 ADDITIONAL INFORMATION Notes Table of Contents Table of Contents Maintenance Record Maintenance Record...