instALLAtiOn instRuctiOns (cont.)
whirlpool Control box ConneCtions
stAnDArD eDition whirlpool
premier eDition whirlpool
Jason’s Standard Edition Whirlpool system features the
best in luxury bathing for the leisure bath industry. To
assure that your bath functions properly, the pump control
box must be properly connected.
NOTe:
For 120v systems, the power cord for the Whirlpool
control box must be plugged into a 120v, 20 amp GFCI
dedicated circuit.
tHE pump cOntROL BOX
The Pump, keypad and Water Level Sensor must be
plugged into the proper receptacles for correct operation
of the system. See
Figure 5
for connections: (A) The
power cord for the pump control box must be plugged into
a 120, 20 amp, GFCI dedicated circuit. (C) The pump’s
power cord will need to be plugged into the control box (B).
(D) Two-pin terminal for installation of the water sensor to
the pump control box. (E) 8-pin mini-DIN terminal for the
Whirlpool keypad.
stAnDARD EDitiOn WHiRLpOOL pARts List
Pump
Pump Control Box
Control Box Stand
Keypad Cable
Keypad
Water Level Sensor
Figure 5
Jason’s Premier Edition Whirlpool system incorporates
all the features of the Standard Edition system and
includes the benefits of a combination pump/heater, ozone
sanitation system, and an LED Chromatherapy light. To
assure that your bath functions properly, the pump control
box must be properly connected.
NOTe:
For 120v systems, the power cord for the Whirlpool
control box must be plugged into a 120v, 20 amp GFCI
dedicated circuit.
tHE pump cOntROL BOX
The Pump, keypad and Water Level Sensor must be
plugged into the proper receptacles for correct operation
of the system. See
Figure 6
for connections: (A) The
power cord for the pump control box must be plugged into
a 120, 20 amp, GFCI dedicated circuit. (C) The pump’s
power cord will need to be plugged into the control box (B).
(D) Two-pin terminal for installation of the water sensor to
the pump control box. (E) 8-pin mini-DIN terminal for the
Whirlpool keypad. (F) 6-pin mini-DIN terminal for the Led
light.
pREmiER EDitiOn WHiRLpOOL pARts List
Pump
Pump Control Box
Control Box Stand
Keypad
Keypad Cable
Water Level Sensor
LED Light Assembly
LED Light Cable
Ozone Sanitation Unit
Figure 6
Note:
This diagram
(Figure 5)
also applies to 50 Hz,
240v controls, and power supply systems. Except that the
Whirlpool pump junction box must be connected into one
dedicated 240v, 20 Amp GFCI circuit.
Note:
This diagram
(Figure 6)
also applies to 50 Hz, 240v
pumps, controls, and power supply systems. Except that
the Whirlpool pump junction box must be connected into
one dedicated 240v, 20 Amp GFCI circuit.