IMPORTANT SAFETY INSTRUCTIONS

InsTruCTIOns PerTaInIng TO The rIsk Of fIre, eleCTrIC shOCk, Or InJury TO Per-

sOns.

This manual contains information and instructions for proper operation and maintenance of your therapy bath.  Failure to follow these 
instructions could result in personal injury, electrical shock, or fire.

warnIng: when using this unit, basic precautions should always be followed, including the following:

reaD anD fOllOw all InsTruCTIOns Carefully

Danger:

 

TO reDuCe The rIsk Of InJury fOllOw These PreCauTIOns: 

a.

  Do not permit children to use this product unless they are closely supervised at all times.

B.

  Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the manufac-

turer.

C.

  The water in a  therapy bath should never exceed 40°C (104°F). Water temperatures between 38°C (100°F) and 40°C (104°F) are 

considered safe for a healthy adult. Use time should be limited to approximately 30 minutes, followed by a shower to cool down. 
Longer exposures may result in hyperthermia. The symptoms of this condition are nausea, dizziness and fainting, and it can be 
fatal. Lower water temperatures are recommended for extended use (exceeding 10 -15 minutes) and for young children.

D.

  Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy, 

pregnant or possibly pregnant women should limit therapy bath water temperatures to 38°C (100°F).

e.

  The  use  of  drugs  or  alcoholic  beverages  before  or  during  therapy  bath  use  may  lead  to  unconsciousness  with  the 

possibility  of  drowning.  Never  use  the  therapy  bath  while  under  the  influence  of  alcohol,  anticoagulants,  stimulants,  
antihistamines, vasoconstrictors, vasodilators, hypnotics, narcotics, or tranquilizers.

f.

  Persons with a medical history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should 

consult a physician before using a therapy bath.

g.

  Persons using medication should consult a physician before using a therapy bath since some medication may induce drowsiness 

while other medication may affect heart rate, blood pressure, and circulation.

Danger:

 

 

To reduce the risk of injury, enter and exit the bath slowly. 

Do not operate this unit unless the suction cover is attached over 

the suction inlet fitting and the jet assemblies are installed.  There should be at least two (2) inches of water above the highest jet 
location during therapy bath operation.

 neVer run unIT Dry.

warnIng:

 

Never operate electrically connected devices in or near the bath. Never drop or insert any object into any opening.

This unit must be connected to a supply circuit that is protected by a GFCI. Such a device should be installed by a licensed electrician 
and should be tested on a regular basis (at least monthly). To test the GFCI push the 

TesT

 button. The GFCI should interrupt the 

power. Push the 

reseT

 button and the power should be restored. If the GFCI fails to operate in this manner, there is the possibility 

of an electric shock. 

DO nOT use. 

Disconnect the unit and have the problem corrected by a qualified service technician. 

To avoid the possibility of personal injury and discoloration of the acrylic surface, the inlet water temperature should not exceed 
40°C (104°F). The bath should be drained after each use. Each bather should start their bath with fresh water. Do not use oil base 
additives in your therapy bath.

CauTIOn: 

Do not use harsh abrasives or solvents for cleaning this unit.

InsTaller/Owner Bears all resPOnsIBIlITy TO COMPly wITh all sTaTe  

anD lOCal CODes when InsTallIng ThIs PrODuCT.

saVe These InsTruCTIOns

 

Jason InternatIonal, Inc.

8328 MacArthur Drive  •  North Little Rock  •  Arkansas  •  72118

www.jasoninternational.com 

Содержание CC550

Страница 1: ...sponsibility Damage sustained in transit is the responsibility of the carrier If damage is discovered If the carton shows sign of damage inspect the product before accepting and describe the problem on the Bill of Lading the carrier must be immediately notified in writing with a request for a representative to inspect the unit Failure of the carrier to respond should be reported to the seller and ...

Страница 2: ...0 55 x 55 x 20 5 59 36 x 17 in 54 1 140 x 140 x 52 223 91 x 43 cm 264 60 x 32 x 20 5 36 36 x 17 in 52 1 152 x 81 x 52 136 91 x 43 cm 254 60 x 36 x 20 5 44 36 x 17 in 56 6 152 x 91 x 52 167 91 x 43 cm 276 60 x 42 x 20 5 49 36 x 17 in 48 1 152 x 107 x 52 185 91 x 43 cm 235 72 x 42 x 20 5 52 36 x 17 in 46 4 183 x 107 x 52 197 91 x 43 cm 227 60 x 32 x 20 5 32 36 x 17 in 50 5 152 x 81 x 52 121 91 x 43 ...

Страница 3: ... 91 x 43 cm 274 72 x 42 x 25 66 36 x 17 in 51 4 183 x 107 x 64 250 91 x 43 cm 251 72 x 48 x 23 100 36 x 17 in 60 8 183 x 122 x 58 379 91 x 43 cm 297 66 x 36 x 25 52 36 x 17 in 60 5 168 x 91 x 64 197 91 x 43 cm 295 72 x 42 x 25 66 36 x 17 in 56 183 x 107 x 64 250 91 x 43 cm 273 60 x 36 x 20 5 40 36 x 17 in 49 4 152 x 91 x 52 151 91 x 43 cm 241 72 x 48 x 20 5 53 36 x 17 in 46 9 183 x 122 x 52 201 91...

Страница 4: ...rt is to be used the bath deck must be leveled at 20 5 52cm from the support floor or the skirt will not fit properly 100 Silicone with mildew resistant properties should 2 be applied between the water resistant backer board and the deck of the bath NOTE If you use a tile flange kit modify the framing to support the bath lip as shown in Figure 1 Install the drain and overflow assembly to the bath ...

Страница 5: ... 8 is level with the bottom of the bath Position the bath in the area of intended installation and cut the equipment supportstrap s toallowtheequipmenttorestfirmlyonthe floor We recommend securing the equipment mounts to the floor with removable fasteners for ease of servicing Protect the acrylic bath surface from damage during 9 installation with a suitable material i e cardboard and or plastic f...

Страница 6: ...the Commonwealth of Massachusetts installation is to be done by a Massachusetts licensed plumber Standard Premier Edition Control Box 120v 4 The pump is prewired to a control box The control box has a 36 91cm cord with plug end If a Jetted Neck Pillow is installed an additional control box will be included The control box es are mounted on a stand that is temporarily secured to the packing board f...

Страница 7: ...uipment ground and should be connected to the neutral bus found in the main breaker box Figure 4 Figure 4A Figure 4B L2 WHITE WITH RED MARK L1 BLACK GND GREEN FROM HEATER FROM CONTROL S L2 240 V L1 NO CONNECTION LOAD NEUTRAL BREAKER BOX Note The load neutral terminal is not used There should be no connection to the load neutral terminal on the GFCI circuit breaker The green wire GND GREEN is the e...

Страница 8: ... acrylic surface during installation to minimize cleanup and prevent surface damage WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing tested for leaks Before water testing the bath 1 make sure any pump unions are hand tight Do not over tighten or use a pipe wrench This will damage the unions and cause leaking If the unit leaks with the...

Страница 9: ...ndard Edition system and includes the benefits of a combination pump heater ozone sanitation system and an LED Chromatherapy light To assure that your bath functions properly the pump control box must be properly connected NOTE For 120v systems the power cord for the Whirlpool control box must be plugged into a 120v 20 amp GFCI dedicated circuit THE PUMP CONTROL BOX The Pump keypad and Water Level...

Страница 10: ...orrect operation of the Whirlpool system See Figure 7 for connections A The junction box for the pump control boxes and heater must be connected into a 240v 20 amp GFCI dedicated circuit B Pre wired power cords to pump C and ozone unit E Eight pin mini DIN terminal for installation of Whirlpool keypad F Six pin mini DIN terminals for the water temperature sensor D and LED light G to the pump contr...

Страница 11: ...or installation of the water sensor to the pump control box E 8 pin mini DIN terminal for the Whirlpool keypad Jason s Premier Edition Whirlpool system incorporates all the features of the Standard Edition system and includes the benefits of a combination pump heater ozone sanitation system and an LED Chromatherapy light To assure that your bath functions properly the pump control box must be prop...

Страница 12: ...ntrol box must be properly connected for the bath to function correctly THE PUMP CONTROL BOX The Pumps Ozone Keypad LED Light and Water Level Sensor must be plugged into the proper receptacles for cor rect operation of the Whirlpool system See Figure 7A for connections A The junction box for the pump control boxes and heater must be connected into a 240v 20 amp GFCI dedicated circuit B Pre wired p...

Страница 13: ... addition to the main control touchpad installed on the bath deck a floating waterproof Universal Remote Control is provided with all Signature Edition Whirlpool baths This remote control provides the same control functions as the bath s main control console plus the bather may remotely operate a TV DVD VCR CD etc Refer to the Instruction Manual provided with the remote control for detailed instru...

Страница 14: ...ATURES AND CONTROLS cont OPERATING INSTRUCTIONS Whirlpool Icon The Pump icon is used to activate the whirlpool pump and the 20 minute timer Pressing the icon the first time starts the pump Pressing the icon again will shut the pump off O Option Whirlpool Option The Option icon is used to operate an LED light if in stalled Press the icon for less than two 2 seconds to turn the lights Off or On Hold...

Страница 15: ...a waterproof floating Universal Remote Control It controls all bath functions plus a TV DVD CD etc which can be heard through the Sound Immersion Transducers optional OPERATING INSTRUCTIONS FEATURES AND CONTROLS cont OPERATING INSTRUCTIONS Whirlpool On Off Icon To control the operation of the whirlpool pump motor press and release for each setting High Medium Low or Off For 50Hz controls ON or OFF...

Страница 16: ...erial number can be found on the front page of this manual or on the small card adhered to the back of the bath just above the equipment HUMIDITY Warning Avoid high humidity levels in your home Mold mildew fungi and bacteria which maybeharmfultohealththriveinareaswith continued high humidity levels therefore every precaution should be taken to make sure your plumbing fixtures including bathtubs th...

Страница 17: ...ary Pump operates but no air is injected into water a Air valves are closed a Open air control valves b Airl line is clogged b Refer to installer dealer Pump operates but water is not being pumped a Suction or discharge blocked a Remove obstruction b Suction air leak System usually surges b Make sure union is tight on suction side of the purmp Pump does not manually shutoff a Defective keypad or c...

Страница 18: ... vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a therapy bath G Personsusingmedicationshouldconsultaphysicianbeforeusingatherapybathsincesomemedicationmayinducedrowsiness while other medication may affect heart rate blood ...

Отзывы: