background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 14 of 18

 

 

 

 

Customer Service :  800.255.5766 

Copyright © 2011 Jason International.

Figure 8

stAnDArD AnD premier eDition whirlpool

 

touChpAD

The Jason Standard and Premier Edition Whirlpool touchpad is used to access all of the 

functions of the pump controls. 

operAting instruCtions, FeAtures, AnD Controls (cont.)

operAting instruCtions

whirlpool

 

icon

The Pump icon is used to activate the whirlpool pump and 

the 20-minute timer.

- Pressing the icon the first time starts the pump.

- Pressing the icon again will shut the pump off.

O

Option

Whirlpool

option

The Option icon is used to operate an LED light (if in-

stalled).

- Press the icon for less than two (2) seconds to turn the 

lights Off or On.

- Hold the icon for more than two (2) seconds to change 

modes.

This function has a two (2) hour timer and remembers the 

last mode.

Содержание CC550

Страница 1: ...sponsibility Damage sustained in transit is the responsibility of the carrier If damage is discovered If the carton shows sign of damage inspect the product before accepting and describe the problem on the Bill of Lading the carrier must be immediately notified in writing with a request for a representative to inspect the unit Failure of the carrier to respond should be reported to the seller and ...

Страница 2: ...0 55 x 55 x 20 5 59 36 x 17 in 54 1 140 x 140 x 52 223 91 x 43 cm 264 60 x 32 x 20 5 36 36 x 17 in 52 1 152 x 81 x 52 136 91 x 43 cm 254 60 x 36 x 20 5 44 36 x 17 in 56 6 152 x 91 x 52 167 91 x 43 cm 276 60 x 42 x 20 5 49 36 x 17 in 48 1 152 x 107 x 52 185 91 x 43 cm 235 72 x 42 x 20 5 52 36 x 17 in 46 4 183 x 107 x 52 197 91 x 43 cm 227 60 x 32 x 20 5 32 36 x 17 in 50 5 152 x 81 x 52 121 91 x 43 ...

Страница 3: ... 91 x 43 cm 274 72 x 42 x 25 66 36 x 17 in 51 4 183 x 107 x 64 250 91 x 43 cm 251 72 x 48 x 23 100 36 x 17 in 60 8 183 x 122 x 58 379 91 x 43 cm 297 66 x 36 x 25 52 36 x 17 in 60 5 168 x 91 x 64 197 91 x 43 cm 295 72 x 42 x 25 66 36 x 17 in 56 183 x 107 x 64 250 91 x 43 cm 273 60 x 36 x 20 5 40 36 x 17 in 49 4 152 x 91 x 52 151 91 x 43 cm 241 72 x 48 x 20 5 53 36 x 17 in 46 9 183 x 122 x 52 201 91...

Страница 4: ...rt is to be used the bath deck must be leveled at 20 5 52cm from the support floor or the skirt will not fit properly 100 Silicone with mildew resistant properties should 2 be applied between the water resistant backer board and the deck of the bath NOTE If you use a tile flange kit modify the framing to support the bath lip as shown in Figure 1 Install the drain and overflow assembly to the bath ...

Страница 5: ... 8 is level with the bottom of the bath Position the bath in the area of intended installation and cut the equipment supportstrap s toallowtheequipmenttorestfirmlyonthe floor We recommend securing the equipment mounts to the floor with removable fasteners for ease of servicing Protect the acrylic bath surface from damage during 9 installation with a suitable material i e cardboard and or plastic f...

Страница 6: ...the Commonwealth of Massachusetts installation is to be done by a Massachusetts licensed plumber Standard Premier Edition Control Box 120v 4 The pump is prewired to a control box The control box has a 36 91cm cord with plug end If a Jetted Neck Pillow is installed an additional control box will be included The control box es are mounted on a stand that is temporarily secured to the packing board f...

Страница 7: ...uipment ground and should be connected to the neutral bus found in the main breaker box Figure 4 Figure 4A Figure 4B L2 WHITE WITH RED MARK L1 BLACK GND GREEN FROM HEATER FROM CONTROL S L2 240 V L1 NO CONNECTION LOAD NEUTRAL BREAKER BOX Note The load neutral terminal is not used There should be no connection to the load neutral terminal on the GFCI circuit breaker The green wire GND GREEN is the e...

Страница 8: ... acrylic surface during installation to minimize cleanup and prevent surface damage WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing tested for leaks Before water testing the bath 1 make sure any pump unions are hand tight Do not over tighten or use a pipe wrench This will damage the unions and cause leaking If the unit leaks with the...

Страница 9: ...ndard Edition system and includes the benefits of a combination pump heater ozone sanitation system and an LED Chromatherapy light To assure that your bath functions properly the pump control box must be properly connected NOTE For 120v systems the power cord for the Whirlpool control box must be plugged into a 120v 20 amp GFCI dedicated circuit THE PUMP CONTROL BOX The Pump keypad and Water Level...

Страница 10: ...orrect operation of the Whirlpool system See Figure 7 for connections A The junction box for the pump control boxes and heater must be connected into a 240v 20 amp GFCI dedicated circuit B Pre wired power cords to pump C and ozone unit E Eight pin mini DIN terminal for installation of Whirlpool keypad F Six pin mini DIN terminals for the water temperature sensor D and LED light G to the pump contr...

Страница 11: ...or installation of the water sensor to the pump control box E 8 pin mini DIN terminal for the Whirlpool keypad Jason s Premier Edition Whirlpool system incorporates all the features of the Standard Edition system and includes the benefits of a combination pump heater ozone sanitation system and an LED Chromatherapy light To assure that your bath functions properly the pump control box must be prop...

Страница 12: ...ntrol box must be properly connected for the bath to function correctly THE PUMP CONTROL BOX The Pumps Ozone Keypad LED Light and Water Level Sensor must be plugged into the proper receptacles for cor rect operation of the Whirlpool system See Figure 7A for connections A The junction box for the pump control boxes and heater must be connected into a 240v 20 amp GFCI dedicated circuit B Pre wired p...

Страница 13: ... addition to the main control touchpad installed on the bath deck a floating waterproof Universal Remote Control is provided with all Signature Edition Whirlpool baths This remote control provides the same control functions as the bath s main control console plus the bather may remotely operate a TV DVD VCR CD etc Refer to the Instruction Manual provided with the remote control for detailed instru...

Страница 14: ...ATURES AND CONTROLS cont OPERATING INSTRUCTIONS Whirlpool Icon The Pump icon is used to activate the whirlpool pump and the 20 minute timer Pressing the icon the first time starts the pump Pressing the icon again will shut the pump off O Option Whirlpool Option The Option icon is used to operate an LED light if in stalled Press the icon for less than two 2 seconds to turn the lights Off or On Hold...

Страница 15: ...a waterproof floating Universal Remote Control It controls all bath functions plus a TV DVD CD etc which can be heard through the Sound Immersion Transducers optional OPERATING INSTRUCTIONS FEATURES AND CONTROLS cont OPERATING INSTRUCTIONS Whirlpool On Off Icon To control the operation of the whirlpool pump motor press and release for each setting High Medium Low or Off For 50Hz controls ON or OFF...

Страница 16: ...erial number can be found on the front page of this manual or on the small card adhered to the back of the bath just above the equipment HUMIDITY Warning Avoid high humidity levels in your home Mold mildew fungi and bacteria which maybeharmfultohealththriveinareaswith continued high humidity levels therefore every precaution should be taken to make sure your plumbing fixtures including bathtubs th...

Страница 17: ...ary Pump operates but no air is injected into water a Air valves are closed a Open air control valves b Airl line is clogged b Refer to installer dealer Pump operates but water is not being pumped a Suction or discharge blocked a Remove obstruction b Suction air leak System usually surges b Make sure union is tight on suction side of the purmp Pump does not manually shutoff a Defective keypad or c...

Страница 18: ... vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a therapy bath G Personsusingmedicationshouldconsultaphysicianbeforeusingatherapybathsincesomemedicationmayinducedrowsiness while other medication may affect heart rate blood ...

Отзывы: