DESCRIPTION OF (CLEARVISION CONTROL PANEL)
A.
Current, parameter and error code display area
B.
Warning indicators
C.
Parameter adjustment knob and button
D.
Cutting mode selection options
E.
Cutting mode selection button
F.
Gas test check button with indicator above
A. Display of parameters and error codes
•
Displays cutting and preset current settings
•
When the factory reset is activated, a countdown is displayed.
•
In engineers mode, parameter settings and their associated
adjustment settings.
•
The machines serial number will be displayed when instructed.
B. Warning indicators
The overheat indicator light indicates the machine has entered overheat protection and has stopped
output, once the machine has cooled down output will be reactivated.
The over
-
current indicator light indicates the machine has entered over
-
current protection and has
stopped output. Turn the machine off and back on again to reset.
C. Parameter adjustment knob
•
Rotate the adjusting knob to adjust the parameters.
•
Rotating the adjusting knob clockwise increases the parameter value, and rotating
the adjusting knob counterclockwise decreases the parameter value.
•
When the adjusting knob is rotated the adjusted parameters are displayed in the
parameter display area.
D, E Selection of cutting modes
Press the cutting mode selection button while not cutting to switch between the three cutting
modes as offered, 2T, 4T and mesh cutting.
If the indicator is on, it indicates the machine is currently in 2T cutting mode.
If the indicator is on, it indicates the machine is currently in 4T cutting mode.
If the indicator is on, it indicates the machine is currently in mesh cutting mode.
F. Gas check test function
•
Press the gas check button (B) while not in cutting state.
•
When the indicator (A) is lit, the machine is in gas check mode.
•
Press the gas check button again or wait 20 seconds . After the indicator light
goes out, the machine has exited gas check mode.
Please Note:
When in any cutting mode, the display window will display the preset cutting current, which can be set
by the operator by rotating the adjustment knob clockwise to increase the current or anti clockwise to
decrease the cutting current. Adjustment cutting current range is 20 ~ 45 amps in 230V mode.