P6-04
Starting frequency
hold time
0.0s
~
100.0s
0.0s
★
62980
P6-05
Starting DC braking
current /
pre-excitation current
0%
~
100%
0%
★
62981
P6-06
Start DC braking time
/
pre-excitation time
0.0s
~
100.0s
0.0s
★
62982
P6-07
Acceleration and
deceleration mode
0: Linear acceleration and
deceleration
1 : S-curve acceleration and
deceleration A
2 : S-curve acceleration and
deceleration B
0
★
62983
P6-08
S-curve start period
time ratio
0.0%
~
(100.0%-P6-09)
30.0%
★
62984
P6-09
S-curve end time
ratio
0.0%
~
(100.0%-P6-08)
30.0%
☆
62985
P6-10
Shutdown mode
0: decelerate to stop
1: free parking
0
☆
62986
P6-11
Start frequency of DC
braking at stop
0.00Hz
~
maximum
frequency
0.00Hz
☆
62987
P6-12
Stop DC braking
waiting time
0.0s
~
100.0s
0.0s
☆
62988
P6-13
Stop DC brake
current
0%
~
100%
0%
☆
62989
P6-14
Stop DC braking time
0.0s
~
100.0s
0.0s
☆
62990
P6-15
brake usage
0%
~
100%
100%
☆
62991
P7 Group keyboard and display
Function
code
Name
Setting range
Factory
default
Attrib
utes
DEC
address
P7-00
Display function
extension 1
Units : power supply voltage
monitoring mode
0: DC bus voltage
1 : Input AC voltage ( with U
letter in front)
00000
☆
63232
P7-01
MF.K key function
selection
0: MF.K is invalid
1 : Switch between
operation panel command
channel and remote
command channel
( terminal command channel
or communication command
channel)
2 : Forward and reverse
switching
3 : Forward jogging
4 : Reverse jogging
0
☆
63233
P7-02
STOP/RESET key
function
0: Only in the keyboard
operation mode, the stop
function of the
STOP/RES key is valid
1 : In any operation mode,
the stop function of the
STOP/RES key is valid
1
☆
63234
6
Janson Controls Technologies(Shenzhen) Co.,Limited
Chapter6 Brief Introduction of Function Parameters
FC100P Series Manual V1.0
-41