background image

Operation Data

  WARNING

FOR YOUR SAFETY - This product must be installed and serviced by a pro fes sion al pool/
spa service technician. The procedures in this manual must be followed ex act ly.  Failure to 
follow warning notices and instructions may result in property damage, serious injury, or 
death. Improper installation and/or operation will void the warranty.

Owner's Man u al

For use with Pool/Spa Combination,
Pool Only/Spa Only, and Dual Equipment
AquaLink

®

 RS Systems with Rev O.2 Firmware

All Button
Control Systems

6

5

9

3

M

 

Содержание Aqualink RS OneTouch

Страница 1: ......

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ...must be performed by a licensed electrician and conform to all national state and local codes When installing and using this electrical equipment basic safety precautions should always be followed inc...

Страница 6: ...fi...

Страница 7: ...elect MENU HELP HELP KEYS When moving through the screens you will have about 15 seconds before the controller will return to the previous screen If you keep the Up or Down arrow button depressed it w...

Страница 8: ...HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3 AUX 4 AUX 5 AUX 6 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF FILTER PUMP OFF FILTER PUMP OFF SPA POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3 AUX 4 AUX 5...

Страница 9: ...the heater is enabled When the LED is red the heater is on and firing It uses the setting from SET TEMP menu or you can increase decrease when enabling Highlight FILTER PUMP and press SELECT Highligh...

Страница 10: ...OFF OFF OFF OFF OFF ENA FILTER PUMP ON SPA POOL HEAT SPA HEAT AUX 1 AUX 2 AUX 3 AUX 4 AUX 5 AUX 6 AUX 7 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF AUX EXTRA FILTER PUMP ON SPA POOL HEAT SPA HEAT SOL...

Страница 11: ...equipment pad must also be set to HEAT MODE In order to use the heat pump the filter pump must be turned on and the heat pump must be in the HEAT MODE HEAT PUMP FILTER PUMP ON SPA POOL HEAT SPA HEAT...

Страница 12: ...equipment pad must also be set to CHILLER MODE The CHILLER selection controls the chilling operation of the heat pump In order to use the chiller mode of the heat pump the filter pump must be turned...

Страница 13: ...RED VIOLET COLOR SPLASH Highlight CHILLER and press SELECT Press the SELECT button to enable disable the CHILLER The CHILLER uses the desired chilling temperature set point Press SELECT to accept the...

Страница 14: ...OOL LIGHT OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON SET COLOR ALPINE WHITE SKY BLUE COBALT BLUE CARIBBEAN BLU SPRING GREEN EMERALD GREEN EMERALD RED MAGENTA GARNET RED VIOLET COLOR SPLASH PLEASE WAIT...

Страница 15: ...tem These states are This feature is used to disable the sprinklers for a period of 24 hours Select SPRINKLERS from the EQUIPMENT ON OFF menu This takes the user to a utility system screen where the 2...

Страница 16: ...stem select DISABLE PROGRAMS from the utility system screen After DISABLE PROGRAMS is selected the system enters the OFF state SPRINKLERS CANCEL TODAY MANUAL START ENABLE PROGRAMS DISABLE PROGRAMS Hig...

Страница 17: ...changed In the example below the SPEED PRESET 3 is turned on and set to 2750 RPM Highlight EQUIPMENT ON OFF and press SELECT Use the UP DOWN arrow keys to highlight the VSP1 SPD ADJ entry and press SE...

Страница 18: ...SELECT to make that degree setting take effect Return to the main menu by using the BACK button FILTER PUMP ON TEMP 2 SOLAR HEAT AUX 1 AUX 2 AUX 3 AUX 4 AUX 5 AUX 6 AUX 7 ALL OFF TEMP 1 OFF OFF OFF OF...

Страница 19: ...ot on 2 speed works only on spa filter pump When programming HIGH and LOW Speeds to operate together think of HIGH SPEED Filter Pump as total duration of filtration time then set Low Speed AUX 2 to op...

Страница 20: ...e this menu to turn on or off one of six mood scene settings Highlight ONETOUCH ON OFF and press SELECT To activate a mood scene setting use the button directly opposite to select the proper mode JAND...

Страница 21: ...ght MENU HELP and press SELECT highlight HELP and press SELECT Highlight DIAGNOSTICS by using the UP DOWN arrow keys and press SELECT Select NEXT and a check of the remote s will be run Select CONTINU...

Страница 22: ...e the PROGRAM menu Highlight CHANGE PROGRAM and press SELECT Program to be changed must be displayed on screen To scroll through multiple programs use the UP DOWN arrows keys to select the program to...

Страница 23: ...y speeds to run during the filtration cycle then by default the variable speed pump will run at the POOL speed setting during its filtration cycle Example 1 The total length of the filtration cycle is...

Страница 24: ...odically activate the pump sample the water and fire the heater to maintain the preset temperature as required Heater must be enabled at all times for this feature to maintain temperature HOURS Highli...

Страница 25: ...e SET AQUAPURE menu select either the SET POOL TO or SET SPA TO and press SELECT Use the UP DOWN arrow keys to set the percentage then press SELECT The SET TIME menu allows the correct time and date t...

Страница 26: ...ITCH SPA LINK DEVICES LOCK UNLK UNLK With this feature the user may restrict access to programs temp settings group settings and system setup One practical use of this feature might be to allow an own...

Страница 27: ...e ARROW KEYS then press SELECT PASSWORD PROTECT PASSWORD PROTECT FILTER PUMP SPA POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3 Use ARROW KEYS then press SELECT FILTER PUMP SPA POOL HEAT SPA HEAT SOL...

Страница 28: ...d Protect will take effect 10 minutes after the last key press PASSWORD PROTECT Use ARROW KEYS then press SELECT PASSWORD PROTECT SYSTEM SPA SWITCH SPA LINK DEVICES Use ARROW KEYS then press SELECT EN...

Страница 29: ...and press SELECT PROGRAM GROUP CUSTOM NAMES GROUP A Use ARROW KEY to change letters Press SELECT to move to next letter BACKSPACE Program groups are useful for changing between specific settings for...

Страница 30: ...WN arrow keys to select the day of GROUP B and press SELECT Press SELECT to return to the MENU HELP screen PROGRAM GROUP GROUP A GROUP B Select group and press SELECT AUTO PGRM GROUP LABEL GROUP MENU...

Страница 31: ...100 output for 24 hours Boost Pool mode will override all programs ALL OFF settings as well as manual operation of the filter pump Boost is not available in Spa Mode Operate the AQUAPURE chlorinator...

Страница 32: ...vices to be controlled mood scene settings When an item is selected the ON will be displayed on the right side of the screen Select all pieces of equipment for that ONETOUCH button then press the BACK...

Страница 33: ...nder CUSTOM LABEL you may type in any name Use the UP DOWN arrow keys to change letters and use SELECT to move to the next letter SYSTEM SETUP ONETOUCH LABEL AUX FREEZE PROTECT AIR TEMP DEGREES C F TE...

Страница 34: ...re chlorine generator Highlight MENU HELP and press SELECT highlight SYSTEM SETUP and press SELECT highlight AquaPure and press SELECT Use the UP DOWN arrow keys to select TIME or MODE If selecting MO...

Страница 35: ...SPLAY Choose setting and press SELECT ENABLED DISABLED SYSTEM SETUP ONETOUCH LABEL AUX FREEZE PROTECT AIR TEMP DEGREES C F TEMP CALIBRATE IN FLOOR CLEAN SOLAR PRIORITY MORE FREEZE PROTECT Use ARROW KE...

Страница 36: ...ture can only be adjusted up 4 degrees Fahrenheit or down 4 degrees Fahrenheit see note below Highlight MENU HELP and press SELECT highlight SYSTEM SETUP and press SELECT highlight TEMP CALIBRATE and...

Страница 37: ...heater will take over to bring the water up to the thermostat setting This menu is used to ENABLE or DISABLE the solar priority SYSTEM SETUP ONETOUCH LABEL AUX FREEZE PROTECT AIR TEMP DEGREES C F TEMP...

Страница 38: ...o be assigned to any auxiliary button This means that whenever you press that auxiliary button a valve turns On pool spa combination models there are two extra JVAs that can be assigned to auxiliary b...

Страница 39: ...1 AUX2 MORE The SPALINK menu allows you to define which equipment is controlled by the buttons on the optional SpaLink s Default settings are spa spa heat Aux1 Aux2 Aux3 Aux4 and Aux5 You can now assi...

Страница 40: ...EAT SOLAR HEAT AUX1 AUX2 AUX3 AUX4 MORE FILTER PUMP SYSTEM SETUP IN FLOOR CLEAN SOLAR PRIORITY PUMP LOCKOUT ASSIGN JVAs DIMMERS SPA SWITCH SPA LINK MORE DUSK SETUP DUSK SETUP OFF AT TIME ADJUST DUSK C...

Страница 41: ...nd advance to the program ON OFF field Use an UP DOWN arrow key to turn the program ON and press SELECT SPRINKLER SETUP GO BACK THIS FEATURE REQUIRES THE ADDITION OF A SPRINKLER MODULE FROM JANDY OK M...

Страница 42: ...urs After setting the WATER DAYS highlight CONTINUE and press SELECT The first SET DURATION screen will appear where valves 1 4 are set Use an UP DOWN arrow key to select the desired VALVE and press S...

Страница 43: ...equipment will go off SYSTEM SETUP SOLAR PRIORITY PUMP LOCKOUT ASSIGN JVAs DIMMERS SPA SWITCH SPA LINK DUSK SETUP MORE ALL OFF TIME ALL OFF TIME FEATURE OFF TIME Use ARROW KEYS to set value Press SEL...

Страница 44: ...has been assigned If the SELECT button is pressed again while on the same selected item the JC JL SL or CL will disappear meaning that a color light is no longer being controlled by the auxiliary Use...

Страница 45: ...K DUSK SETUP ALL OFF TIME PRODUCT INFO CLEAR MEMORY HEAT PUMP DEVICE RUNTIME MORE DEVICE RUNTIME SPA MODE CLEAN MODE ONETOUCH 3 SPA AUX1 AUX2 AUX3 AUX4 MORE DEVICE RUNTIME SPA MODE CLEAN MODE ONETOUCH...

Страница 46: ...SPA LINK DUSK SETUP ALL OFF TIME PRODUCT INFO CLEAR MEMORY HEAT PUMP DEVICE RUNTIME MORE HEAT PUMP SETUP Choose setting and press SELECT HEAT MODE CHILL MODE HEAT PUMP SETUP HEAT COOL MODE MUST BE SE...

Страница 47: ...PA LINK DUSK SETUP ALL OFF TIME CLEAR MEMORY DEVICE RUNTIME MAINTAIN TEMP ONETOUCH PRODUCT INFO The SEASONAL ADJUST menu is a feature that will automatically adjust filtration cycles chlorine levels w...

Страница 48: ...e started FILTER PUMP PGM 1 of 1 ON 8 00 AM OFF 4 00 PM ALL DAY ADD DELETE CHANGE PROGRAM PROGRAM PROGRAM FILTER PUMP PGM 1 of 1 ON 8 00 AM OFF 6 00 PM ALL DAY ADD DELETE CHANGE PROGRAM PROGRAM PROGRA...

Страница 49: ...LECT when required The RS InterLink allows a single controller to access two power centers on the AquaLink RS system For ease of operation it is suggested that each power center be given a custom prod...

Страница 50: ...le speed pumps In the PUMP SETUP menu the user can select each pump 1 4 and configure how the pump s are to be used For example if the pump is to be used as a POOL PUMP SPA PUMP dual equipment systems...

Страница 51: ...ired LIMIT then press SELECT There are eight 8 default speed presets for each variable speed pump In VSP SETTINGS menu highlight SPEED LABELS and press SELECT highlight PUMP1 and press SELECT Use the...

Страница 52: ...setting of this preset If dip switch S1 3 is OFF then the default label for this preset is SPEED4 On Pool Spa Combo systems the default label is POOL HEAT When the pool heater is enabled the pump wil...

Страница 53: ...spa pump is supposed to turn on this preset is selected On a dual equipment system when a pump is configured as a POOL PUMP the default label for preset 2 is SPEED2 For the Pool Pump if dip switch S1...

Страница 54: ...he Pool Pump when the In Floor clean mode is enabled and the pump is running it will be running at this preset speed For the Spa Pump the default label is SPEED8 This menu allows the user to assign a...

Страница 55: ...hen press SELECT Use the UP DOWN arrow keys to highlight SET SPEED then press SELECT Use the UP DOWN arrow keys to set value then press SELECT This menu allows for the user to set the length of time t...

Страница 56: ...ate Return to pool mode to activate the waterfall Also if the pool cleaner is on it will turn off during spillover operation When Dip Switch S1 3 is in the ON position the Aux 3 relay socket is activa...

Страница 57: ...om pool position to spa position or vice versa before activating the filter pump This message indicates that the Controller has been locked out from the power center and is not operational Service mod...

Страница 58: ......

Страница 59: ......

Страница 60: ......

Страница 61: ...and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizing chemicals suc...

Страница 62: ...ATE OF INSTALLATION INSTALLER INFORMATION INITIAL PRESSURE GAUGE READING WITH CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL SERIAL NUMBER CONTROL PANEL MODEL SERIAL NUMBER NOTES EQUIPMENT INFORMATIO...

Страница 63: ...abel Label removed FRZ PROTECT Press ENTER to remove all devices except the pump from freeze protection or cancel to abort PROGRAMS CANCEL SOME CANCEL ALL Select device to be canceled SOLAR HEAT PRIOR...

Страница 64: ...IR TEMP FRZ PROTECT SPA LINK SPA SWITCH MAIN LABEL MENU SEE SECTION 8 FOR AN EXPANDED LIST SET DIMMERS SELECT EQUIPMENT ALL OFF LABEL AUX AQUAPURE DAYLIGHT SAVINGS DIAGNOSTICS IN FLOOR CLN SOLAR HEAT...

Страница 65: ...the heater from damage whenever the heater has red and has been off for less than ve 5 minutes PUMP WILL TURN ON AFTER DELAY This message is displayed during pool spa switching The AquaLink RS waits 3...

Страница 66: ...irculating to pool The spillover requires that water is circulating to the pool in order for it to operate Return to pool mode to activate the waterfall Also if the pool cleaner is on it will turn off...

Страница 67: ...rogram the AquaLink RS display will tell you how many programs there are for example if there are three programs the AquaLink RS display will read 3 PROGRAMS EXIST 5 The AquaLink RS display will read...

Страница 68: ...ettings Stored values include auxiliary labels all programs freeze protection settings remote settings and thermostat settings The time and date will not be cleared Only use the Clear Memory Menu as n...

Страница 69: ...is required 4 25 1 To operate In Floor Return Valve Switching Under SYSTEM SETUP use the FORWARD or BACK arrow to move to IN FLOOR CLN Use the FORWARD or BACK arrow button to turn IN FLOOR CLN on or o...

Страница 70: ...tton of the auxiliary that you want to activate the JVA 4 23 Set Color Lights Menu The COLOR LIGHTS menu is used to select the color light type Jandy Pentair SAmTM SAL or Color Logic and to assign the...

Страница 71: ...buttons to adjust the temperature display up or down NOTE This will not change the temperature of the water only the display of the temperature on the AquaLink RS display Press ENTER when the desired...

Страница 72: ...eze protected as a default You can change the temperature at which freeze protection will activate between 34 F and 42 F For example if you want freeze protected equipment to turn on when the air temp...

Страница 73: ...on the system the buttons on the second switch will be buttons 5 8 and the buttons on the third Spa Side Switch will be buttons 9 12 4 16 SpaLink RS Menu The SPA LINK menu allows you to define which e...

Страница 74: ...t to the desired label press ENTER NOTE ON LABELING LIGHTS Since many different types of lights can be controlled by the AquaLink RS there is a special submenu for lights To access it follow the steps...

Страница 75: ...rcentage 1 Press the Menu button use the BACK or FORWARD arrow button to display SET AQUAPURE menu press ENTER 2 Inside the SET AQUAPURE menu select either SET POOL or SET SPA then press ENTER 3 Use t...

Страница 76: ...ent in each group Use the PROGRAM GROUP Menu to switch between PROGRAM GROUP A and PROGRAM GROUP B Group A is the default Program Group A or B will not appear unless PROGRAM GROUP has been selected Co...

Страница 77: ...limit the time of day the Maintain Temperature feature will be active NOTE You cannot set the solar temperature Solar heating will activate when the solar button is pressed the solar temperature is at...

Страница 78: ...pecific on and off hour and minute You can program each piece of equipment for multiple on off times each day 4 2 1 To set automatic on and off times 1 Press the MENU button Use the FORWARD and BACK b...

Страница 79: ...rotection protects equipment from damage caused by freezing water Turn the Air Temperature display on and off air temperature sensor must be installed Change between Celsius and Fahrenheit temperature...

Страница 80: ...maintenance low temperature It must be set lower than TEMP1 If TEMP2 is on and TEMP 1 is activated TEMP2 will turn off and its LED will ash When TEMP1 is turned off again TEMP2 will reactivate 3 4 2...

Страница 81: ...ill affect the operation of the AUX Button See Section 6 2 for details on Special Auxiliary Labels 3 2 Spa Button The SPA button switches water circulation from pool to spa pool and spa combo models o...

Страница 82: ...control will operate as follows HIGH SPEED Filter Pump must be on before LOW SPEED Filter Pump button as well as the Spa button turns it to HIGH SPEED LOW SPEED AUX 2 button toggles back and forth fro...

Страница 83: ...attery located in the power center enclosure All other programs and Menu setups do not require battery to store information 2 3 Power Interruption In the event there is a power interruption and the Aq...

Страница 84: ...cis Ne pas utiliser une cuve de relaxation imm diatement apr s un exercice fatigant L utilisation prolong e d une cuve de relaxation peut tre dangereuse pur la sant Ne pas placer d appareil lectrique...

Страница 85: ...en or missing Never replace a suction fitting with one rated less than the flow rate marked on the equipment assembly WARNING To Reduce the Risk of Injury a The water in a spa should never exceed 104...

Страница 86: ...Menu 14 4 11 System Setup Menu 14 4 12 AquaPure Menu 14 4 13 Label AUX Menu 15 4 14 Boost Hours of Operation Menu 15 4 15 Spa Side Switch Menu 16 4 16 SpaLink RS Menu 16 4 17 Freeze Protection Menu 1...

Страница 87: ......

Страница 88: ...al must be followed exactly Failure to follow warning notices and instructions may result in property damage serious injury or death Improper installation and or operation will void the warranty Owner...

Отзывы: