When a pump is configured to be either a POOL PUMP or a SPA PUMP, the speed presets will be labeled as shown in
the table below.
On a dual equipment system when a pump is configured as a POOL PUMP, the default label for preset #1 is POOL.
This label is tied to the pool filtration mode. Anytime the pool pump is supposed to turn on, this preset is selected.
On a dual equipment system when a pump is configured as a SPA PUMP, the default label for preset #1 is SPEED1.
On a dual equipment system when a pump is configured as a SPA PUMP, the default label for preset #2 is SPA. This
label is tied to the spa filtration mode. Anytime the spa pump is supposed to turn on, this preset is selected.
On a dual equipment system when a pump is configured as a POOL PUMP, the default label for preset #2 is SPEED2.
For the Pool Pump, if dip switch S1-1 is ON, then the default label for this preset is CLEANER. Anytime the cleaner
mode is turned on the pump will run at the speed setting of this preset. If dip switch S1-1 is OFF, then the default label
for this preset is SPEED3.
For the Spa Pump the default label is SPEED3.
Each of the eight (8) speed presets has a label and each of those labels can be changed from the default value.
In the SPEED SETTINGS menu, highlight LABEL SPEEDS and press SELECT. Use the UP/DOWN arrow keys
to highlight the desired PUMP, then press SELECT. Use the UP/DOWN arrow keys to highlight either GENERAL
LABELS or CUSTOM LABELS and then press SELECT.