This section describes how to program a variable speed pump.
A variable speed pump can be programmed to run at any one of its eight (8) speeds. If the variable speed pump is used
for pool filtration, then it will be powered from the FILTER PUMP relay. Therefore to program the variable speed
pump you must first set a program time for the FILTER PUMP, then you need to program the pump speeds to turn
on/off during the FILTER PUMP cycle. If you do not program any speeds to run during the filtration cycle, then by
default the variable speed pump will run at the POOL speed setting during its filtration cycle.
Example:
1. The total length of the fi ltration cycle is to be from 8am to 5pm, therefore, program the FILTER PUMP to turn on
at 8am and to turn off at 5pm.
2. To run the variable speed pump at the SPEED3 setting from 8am to 1pm, highlight and select VSP SPD1 PGM,
then highlight and select SPEED3, program it to turn on at 8am and off at 1pm.
3. To run the variable speed pump at the SPEED4 setting from 1pm to 5pm, highlight and VSP SPD1 PGM, then
highlight and select SPEED4, program it to turn on at 1pm and off at 5pm.