Highlight the SET WATER DAYS and press SELECT. Use an UP/DOWN arrow key to select the DAY to water and
press SELECT. An "X" is displayed with each enabled water day.
The Sprinkler Control module will control up to eight valves, plus one master valve. When a program is run, the
master valve always activates 1-2 seconds before the first programmed valve in the program. Valves are then activated
in numerical order for a time equal to their duration setting. There is a 1-2 second delay between valve activations.
Valve durations are adjustable from OFF to 240 minutes, in increments of 1 minute from OFF to 10 minutes,
increments of 10 minutes from 10 to 60 minutes, and increments of 30 minutes from 60 to 240 minutes (4 hours).
After setting the WATER DAYS, highlight CONTINUE and press SELECT. The first SET DURATION screen will
appear, where valves 1-4 are set. Use an UP/DOWN arrow key to select the desired VALVE and press SELECT to
highlight the DURATION field. Use an UP/DOWN arrow key to set the DURATION time and press SELECT.
SPRINKLER SETUP
Highlight an item
and press SELECT
PROGRAM 2: ON
START: 9:30AM
SET WATER DAYS
SET DURATION
SET WATER DAYS
PROGRAM 2
CONTINUE
SUN
MON
TUE
WED
THU
FRI
SAT
SET WATER DAYS
PROGRAM 2
CONTINUE
SUN X
MON
TUE
WED
THU
FRI
SAT
To continue onto Valves 5-8, highlight NEXT and press SELECT. In the second SET DURATION screen, set Valves
5-8 in the same manner as Valves 1-4.
SET DURATION
PROGRAM 2
Highlight an item
and press SELECT
VALVE 1: 10 MIN
VALVE 2: OFF
VALVE 3: OFF
VALVE 4: OFF
NEXT
SET DURATION
PROGRAM 2
Highlight an item
and press SELECT
VALVE 5: 10 MIN
VALVE 6: OFF
VALVE 7: OFF
VALVE 8: OFF
CONTINUE