Equipment Description
3
Revision 1.0 - 7-May-02
HUB24 Series Dimmer
Operating Manual
2
Equipment Description
Front panel layout
Figure 2.1
1.
Phase Power LEDs: Three different coloured LEDs (one for each phase) indicate
that the mains supply phases are available. Red for phase A, White for phase B and
Blue for phase C.
2.
Display: Large graphics LCD, used to display dimmer status information and to
control the menus.
3.
Menu buttons: 2 buttons are used to navigate the menus and save changes.
4.
Encoder wheel: This detent action control knob is used to select items from the
menus and to select the channel levels or chase rate (depending on the operating
mode).
5.
DMX IN/THRU connectors: A standard five pin AXR connector receives DMX-
512 signals from a control source and a second “Thru” connector links signal to
other DMX equipment. See section 8.1 for wiring details.
6.
DMX OPTO-OUT connectors: Two fully isolated DMX outputs, using standard
five pin AXR connectors. See section 8.1 for wiring details.
7.
Dimmer RCD protection: A three phase RCD protects the dimmer outputs. It
must not be used as load break switch.
8.
Distribution RCD protection: A three phase RCD protects the power distribution
outputs. It must not be used as load break switch.
9.
Dimmer circuit breakers: 15 circuit breakers, one for each dimmer output.
10. Distribution circuit breakers: 3 circuit breakers, each one supplies a row of 3
separate distribution outputs.
11. Dimmer Output connectors: 15 dimmer output sockets.
12. Distribution Output connectors: 9 distribution output sockets.