-118-
Use control board memory to
restore parameters
501
Use keyboard memory 1 to restore
parameters
502
Use keyboard memory 2 to restore
parameters
503
•
1: Restore default settings except motor parameters
If PP.01 is set to 1, most function codes are restored to the default settings except motor
parameters, frequency reference resolution (P0.22), fault records, accumulative running time
(P7.09), accumulative power-on time (P7.13) and accumulative power consumption (P7.14).
•
2: Clear records
If PP.01 is set to 2, the fault records, accumulative running time (P7.09), accumulative power-on
time (P7.13) and accumulative power consumption (P7.14) are cleared.
•
3: Restore factory settings including motor parameters
If PP.01 is set to 3, most function codes are restored to the default settings including motor
parameters.
•
4: Backup current user parameters to control board memory
If PP.01 is set to 4, the current parameter settings are backed up in control board memory, helping
you to restore the setting if incorrect parameter setting is performed.
•
5: Backup current user parameters to keyboard memory 1
•
6: Backup current user parameters to keyboard memory2
•
501: Use control board memory to restore parameters
If PP.01 is set to 4, the previous backup user parameters in control board memory are restored.
•
502: Use keyboard memory 1 to restore parameters
•
503: Use keyboard memory 2 to restore parameters
PP.02
Inverterparameter display
property
One’s
place
Group d display selection
01
★
No display
0
Display
1
Ten’s
place
Group b display selection
No display
0
Display
1
PP.04
Parameter modification
property
Modifiable
0
0
☆
Not modifiable
1
It is used to set whether the parameters are modifiable to avoid mal-function. If it is set to 0, all
parameters are modifiable. If it is set to 1, all parameters can only be viewed.
Содержание DLB1-0004T4G
Страница 10: ... 10 Graph 1 5 5 5 7 5KW product outline dimensions Graph 1 611 18 5KW product outline dimensions ...
Страница 11: ... 11 Graph 1 722 30KW product outline dimensions Graph 1 837 55KW product outline dimensions ...
Страница 12: ... 12 Graph 1 875 110KW product outline dimensions Graph 1 9 132 160KW product outline dimensions ...
Страница 14: ... 14 2 Wirings 2 1 Standard wiring diagrams Graph 2 8 0 4 18 5KW inverter wiring diagram ...
Страница 15: ... 15 Graph 2 922 400KW inverter wiring diagram ...
Страница 159: ... 159 ...