-137-
7.3 Communicationaddresses
Function codeaddress rules (EEPROM):
High place bytes
: 00~0F (P0~PF, change P to 0), 40~4F (B0~BF, change B to 4)), 70~7F
(D0~DF).
Low place byte
: 00~FF.
For example: P3.12, the address is expressed as F30C.
Note:
PF group: not readable or editable;
Group d: read-only and cannot be changed.
In addition, frequent EEPROM storage will reduce the life of the EEPROM.Some functions
can be realized by changing the value of RAM. User needs to change high place byte A to 4.
Address
Function
1000
Communication setting value(-10000~10000)(decimal)
1001
Running frequency
1002
DC bus voltage
1003
Output voltage
1004
Output current
1005
Output power
1006
Output torque
1007
Running speed
1008
DI input state
1009
DO output state
100A
AI1 voltage
100B
AI2 voltage
100C
AI3 voltage
100D
Counter input
100E
Length input
100F
Load speed
1010
PID setting
1011
PID feedback
1012
PLC sequence
1013
Input pulse frequency, unit0.01kHz
1014
Feedback speed, unit0.1Hz
1015
Remaining running time
1016
AI1 voltage before correction
1017
AI2 voltage before correction
1018
AI3 voltage before correction
1019
Linear speed
Содержание DLB1-0004T4G
Страница 10: ... 10 Graph 1 5 5 5 7 5KW product outline dimensions Graph 1 611 18 5KW product outline dimensions ...
Страница 11: ... 11 Graph 1 722 30KW product outline dimensions Graph 1 837 55KW product outline dimensions ...
Страница 12: ... 12 Graph 1 875 110KW product outline dimensions Graph 1 9 132 160KW product outline dimensions ...
Страница 14: ... 14 2 Wirings 2 1 Standard wiring diagrams Graph 2 8 0 4 18 5KW inverter wiring diagram ...
Страница 15: ... 15 Graph 2 922 400KW inverter wiring diagram ...
Страница 159: ... 159 ...