QUESTIONS?
USE THIS EASY TROUBLESHOOTING GUIDE
questions
PROBLEM
TOP BURNER DOESN’T
LIGHT
PROBABLE CAUSE
1. Range not connected to
power supply.
2. Clogged burner port.
3. Burner improperly
positioned.
POSSIBLE SOLUTION
1. Connect range to wall outlet;
check circuit breaker or fuse
box.
2. Clean burner port with a
straight pin.
3. Place burner in proper
position on valve and burner
hanger.
1. Lack of primary air due to
incorrect air shutter
adjustment.
2. Blocked, dirty primary air
openings or blocked
burner ports.
3. An improperly aligned
orifice hood is reducing
primary air injection.
4. Incorrect orifice size.
5. Faulty drilling or a dirty
orifice.
1. Open air shutters to
eliminate yellow tips.
Caution: too much air will
cause lifting, noisy
flames. A balance must be
maintained. (See page 44.)
2. Clean and readjust burner.
3. Align with burner venturi
and tube.
4. Replace with correct
orifice size.
5. Clean orifice or replace
faulty drilled orifice.
YELLOW TIPPING ON
FLAME; PRODUCES SOOT
AND BLOCKS FLUE
OPENINGS
1. Occurs when the flow
velocity of air/gas mixture
exceeds flame velocity.
(Flame velocity is the
speed at which a flame
moves through a fuel/air
mixture.)
1. Reduce air shutter
opening. Caution: Over
reduction of air will cause
yellow flames. Proper
fuel/air balance must be
maintained. (See page 44.)
LIFTING FLAMES;
FLAMES RISE FROM THE
PORTS AND BURN ABOVE
THE PORTS, ALSO KNOWN
AS NOISY FLAME
48