This document is the property of IXSEA and shall not be reproduced nor transmitted without written approval
7.3.1 Transducer
cap
The transducer cap must not be greasy, clean with liquid soap to remove any grease or deposits. Do not use
alcohol or petrol-based solvents on the neoprene casing.
7.3.2 O-ring
seals
It is advised to clean the O-ring seals as well as the seal housings and to grease them with silicone before
closing the acoustic release. Replace damaged or scratched seals (Refer to § Maintenance).
7.4 STORAGE
The device must be correctly sealed and stored in a clean area. If the user wants to keep the batteries installed
during storage, it is recommended to inhibit PINGER ON function. The storage with batteries removed is the
advised storage mode for long storage periods. Refer to the previous paragraphs to open the equipment and
remove the batteries.
7.5 TROUBLESHOOTING
•
Transducer
test
•
Reception
test
•
Transmission
test
•
Battery voltage test and current measurement in stand-by/ listening mode
8. CUSTOMER SUPPORT
Customer’s technical support on this product is available:
•
by e-mail :
•
by phone through IXSEA 24/7 hot-line :
+33 (0)1 30 08 98 98 for EMEA
+1 781 937 8803 or +1 888 660 8836 (toll free) for US
+65 6747 7027 for Asia
Contact IXSEA support for any request on technical matters related to this product.
IXSEA customer’s support commits to provide a quick response to your query.