M U _ O C E A N O 2 5 0 0 S - U n i v e r s a l _ U K
I ss u e 10
3 0 •05 •07 8
This document is the property of IXSEA and shall not be reproduced nor transmitted without written approval
Release option by acoustic telecommand
PFR = Pinger Frequency.
In the case of a release with Pinger, the operating duration is set at 3 minutes. Use the PINGER ON command
to transmit PFR for an unlimited duration. Only the PINGER OFF command allows these transmissions to be
stopped.
The following parameters are factory-selected and cannot be changed by the user :
•
PFR = 8 kHz or 12 kHz (as expected by the user)
•
Pinger rate = 5 seconds.
Motor
rotation
AR
transmission
20 ms
Standard
CAF
acknowledgment
CAF execution
Standard release
AR reception
3 sec
# 2 sec
Motor
rotation
AR
transmission
20 ms
Standard
CAF
acknowledgment
CAF execution
Release with Pinger
AR reception
3 sec
Pinger
transmission
duration
Pinger
rate
# 2 sec
PFR PFR
3 sec