VECTOR 8 GENSET FVAE2885X*A100 MAINTENANCE PLAN
PRIME POWER
Prime Power is the maximum power available at variable loads for an unlimited number of hours. The average power available
during a 24 hour operating period should not exceed 80% of the prime power between the recommended servicing intervals in
standard environmental conditions.
An overload of 10% for 1 hour for every 12 hours of operation.
STAND-BY POWER
This is the maximum power available for a period of 500 hours/year with an average load factor of 90% of the stand-by power.
No type of overload is permitted for this usage.
CONTINUOUS POWER
Contact the Iveco Motors sales organization.
SECTION 3 - INDUSTRIAL APPLICATION
81
VECTOR 8 ENGINES
Print P2D32V001E
Base - April 2006
Continuous / Prime
Stand-By
Periodic Checks
100 h
1 month
Hourly intervals
h
Time intervals
Hourly intervals
h
Time intervals
First level service
1000
1 year
500
1 year
Second level service
5000
2 years
1000
2 years
General overhaul
25000
10 years
2000
10 years
For special applications (heavy operating conditions, T
ambient
>40
°
C) the following reduction in these intervals is required:
Periodic checks
0%
First level service
0%
Second level service
- 40%
General overhaul
- 40%
LIST OF OPERATIONS
PERIODIC CHECKS
Check oil level/top up (Urania Turbo LD)
Check coolant level/top up
Check whether air/oil/diesel filter blocked warning lights are on (if wired)
Check water in diesel prefilter warning light
Содержание VECTOR 8
Страница 1: ...VECTOR SERIES Industrial application VECTOR 8 Technical and Repair manual ...
Страница 10: ...2 VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Страница 13: ...5 VECTOR 8 ENGINES Print P2D32V001E Base April 2006 UPDATING Section Description Page Date of revision ...
Страница 14: ...6 VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Страница 16: ...2 SECTION 1 GENERAL SPECIFICATIONS VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Страница 18: ...4 SECTION 1 GENERAL SPECIFICATIONS VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Страница 28: ...14 SECTION 1 GENERAL SPECIFICATIONS VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Страница 30: ...2 SECTION 2 FUEL VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Страница 60: ...8 SECTION 3 INDUSTRIAL APPLICATION VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Страница 62: ...10 SECTION 3 INDUSTRIAL APPLICATION VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Страница 94: ...42 SECTION 3 INDUSTRIAL APPLICATION VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Страница 96: ...44 SECTION 3 INDUSTRIAL APPLICATION VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Страница 106: ...54 SECTION 3 INDUSTRIAL APPLICATION VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Страница 107: ...THIRD PART DIAGNOSTICS SECTION 3 INDUSTRIAL APPLICATION 55 VECTOR 8 ENGINES Print P2D32V001E Base April 2006 ...
Страница 108: ...56 SECTION 3 INDUSTRIAL APPLICATION VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Страница 129: ...FOURTH PART PLANNED MAINTENANCE SECTION 3 INDUSTRIAL APPLICATION 77 VECTOR 8 ENGINES Print P2D32V001E Base April 2006 ...
Страница 130: ...78 SECTION 3 INDUSTRIAL APPLICATION VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Страница 191: ...SECTION 5 TOOLS 1 VECTOR 8 ENGINES Print P2D32V001E Base April 2006 SECTION 5 Tools Page TOOLS 3 ...
Страница 192: ...2 SECTION 5 TOOLS F4AE NEF ENGINES Base April 2006 Print P2D32V001E ...
Страница 204: ...2 APPENDIX F4AE NEF ENGINES Base April 2006 Print P2D32V001E ...