Press the “
M
” key to advance to
MODE 6
and immediately lift the loaded bucket or forks just above
the ground.
•
(Activate the lift control valve, as you would do during the normal lifting operation).
MODE
Five Digits Load Weight Readout Display
6
•
The display will go blank. Wait a few seconds.
(Do not move forks, do not tilt or activate side shift
lever)
•
Within a 3-5 seconds the display will show the value of the calibrated “known load weight”, in our
case 1500. If you lower the load to the ground system will go automatically into operational mode.
•
Number 8 will be shown in the MODE window. System is calibrated and ready to be used!
System Weigh Calibration Function is finished!