![IVDT SkidWeigh ED2-CC Series Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/ivdt/skidweigh-ed2-cc-series/skidweigh-ed2-cc-series_manual_2097224004.webp)
4
2.
The pressure transducer must be installed in the
hydraulic line between the lift control valve
and the lift cylinder(s).
If possible locate a hydraulic fitting that can be removed to allow drilling
and tapping. Failing this a hydraulic adaptor can be fitted. Connect appropriate fitting and hose to
allow pressure transducer to be mounted in a safe location. Connect the transducer to the hydraulic
line. Start the engine and bleed the air from the line, then tighten the transducer
Pressure Transducer Cable
1 Red, 2 White,
3 Black
Seven Wires Cable
Electrical connections
(For Vehicle Input Voltage’s from 12 to 55V DC)
RED Wire
of pressure transducer cable to RED WIRE of the 7 wires cable from the indicator
BLACK Wire
of pressure transducer cable to BLACK WIRE of the 7 seven wires cable from the
indicator
WHITE Wire
of pressure transducer cable to WHITE WIRE of the 7 wires cable from the indicator
ORANGE Wire
(+)
Connect to the ignition switch “ON” position
BROWN Wire
(-)
Connect to battery negative (Electric motor powered vehicles) or to the vehicle
chassis of combustion engine powered vehicles.
BLUE
and
GREEN
Wires: Connection to the external overload warning, over/under load weight.
This is N.O. (normally open relay contacts, maximum 1A resistive load).