![IVDT SkidWeigh ED2-CC Series Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/ivdt/skidweigh-ed2-cc-series/skidweigh-ed2-cc-series_manual_2097224008.webp)
8
Calibration of Loaded Bucket / Forks
(Example: Known Load Weight is 1500)
•
At this point, drive the vehicle into the skid with a known load weight. (If this is a typical pallet with
known weight, make sure that the forks are in the pallet and are
lowered to the ground
. In the
case of the bucket
make sure that the loaded bucket fully crowded and
lowered to the ground.
•
Start entering a known load weight into the digital indicator. The first value of the known load
weight can be entered by pressing the “
⇑
⇑
⇑
⇑
” key.
•
The number will increment from 0 to 9 and will wrap around.
•
To enter a second digit from the right, press the “
M
” key and the
MODE
digit will increment to 2.
•
Keep pressing “
⇑
⇑
⇑
⇑
” to enter a second value of known load weight.
•
Repeat this procedure until the
MODE
digit display is showing
5
.
Note:
In our example known load weight is 1500.
Make sure that you enter
0
in
MODE 5,
since the
known load weight has only 4 digits as in our example of 1500
. This value of 1500 could represent
kilograms or pounds.
MODE
Five Digits Load Weight Readout Display
1
0
MODE
2
0
MODE
3
5
MODE
4
1
MODE
5
0
•
Before going to
MODE 6
please make sure that the “Known load weight” (in our example, 1500
pounds or kilograms) is ready to be lifted. The loaded forks must be on the ground (No hydraulic
pressure in the lifting hydraulic circuit).