![IVDT SkidWeigh ED2-CC Series Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/ivdt/skidweigh-ed2-cc-series/skidweigh-ed2-cc-series_manual_2097224014.webp)
14
MODE
Five Digits Load Weight Readout Display
7
0
•
Using the same keys “
M
” and “
⇑
⇑
⇑
⇑
”, enter the “
Overload Weight Value
”. In our example it’s 4000.
You will note that the
MODE 7
digit remains throughout this operation. (Make sure that 5
th
digit is 0)
MODE Five Digits Load Weight Readout Display
7
0
MODE
7
0
MODE
7
0
MODE
7
4
MODE
7
0
On the last shift, (Utilizing “
M
” key, left shift) the
MODE 7
digit will turn off. The “Overload Weight Value” will
be successfully stored in the memory.
MODE
Five Digits Load Weight Readout Display
7
0
4
0
0
0
The entered value of 4000 will be shown briefly on the digital display and the unit will return to the
normal operational
MODE 8
.
MODE
8
The System Calibration and the “Overload Warning Value”
Have Been Successfully Stored in the Memory