Size
D
S
perm
750 min
-1
1000 min
-1
1200 min
-1
1450 min
-1
1750 min
-1
2000 min
-1
2400 min
-1
2800 min
-1
SLH-4G 30xx 0.32 mm
0.27 mm
0.25 mm
0.23 mm
0.21 mm
0.19 mm
0.18 mm
0.16 mm
SLH-4G 40xx 0.36 mm
0.31 mm
0.28 mm
0.26 mm
0.24 mm
0.22 mm
0.20 mm
0.19 mm
5.5.3 Taking into account peak height changes
With cold alignment take into account peak height changes under the influence of
the operating temperature according to the following figures. As soon as the
pump system has reached the operating temperature following start-up, it is nec-
essary to check the alignment (hot alignment) once again.
To determine the material design of the pump
pump data sheet.
Abbreviation
Meaning
Tm
Mean temperature value Tm = (T2-T1)/2
T1
Ambient temperature
T2
Medium temperature
ΔH
Peak height change
Explanation of the abbreviations
Installation and connection
Type SLH-4G, SLHS-4G
35