6.3.1 CIP cleaning/sterilising at CIP temperature below 80 °C
Prerequisites:
n
For pumps with sealing system: Sealing system in operation.
n
Pump stopped.
1.
Switch pipeline system to CIP medium.
2.
Chapter 6.2.2 ‘Switching on’ on page 53
3.
Clean pipeline system and pump.
4.
Chapter 6.2.3 ‘Switching off’ on page 55
5.
Remove all traces of the CIP medium.
6.3.2 CIP cleaning/sterilising at CIP temperature above 80 °C and pump with sealing
system or quench system
Prerequisites:
n
Sealing/quench system in operation.
n
Pump stopped.
NOTICE!
Property damage resulting from pump jamming!
–
Warm up pump whilst stationary.
1.
Switch pipeline system to CIP medium.
2.
Chapter 6.2.2 ‘Switching on’ on page 53
3.
If the pump is cold:
n
Stop the pump for approx. 10 minutes.
n
Wait for casing temperature above 60 °C.
n
Restart the pump.
4.
Clean pipeline system and pump.
5.
Chapter 6.2.3 ‘Switching off’ on page 55
6.
Remove all traces of the CIP medium.
6.3.3 CIP cleaning/sterilising at CIP temperature above 80 °C and pump without sealing
system, without quench system
Prerequisite:
n
Pump stopped.
NOTICE!
Material damage due to overheated mechanical seal!
–
Only clean/sterilise pump when it is stopped.
–
Cleaning time shorter than 30 minutes.
Operation
Type SLH-4G, SLHS-4G
56
01/2016 JPB Rev. 5