Safety
DANGER!
Mortal danger in the event of non-compliance with the docu-
mentation!
–
Observe all of the documentation relating to the pump and all
system components.
–
Reading and observing the documentation is a prerequisite for
proper use of the product.
2.1 Intended use
n
Use system exclusively for pumping the agreed pumped medium (
pump
data sheet).
n
Adhere to operating limits (
pump data sheet).
n
Avoid dry running:
–
Ensure that the pump is only put into operation with pumped medium and
is not operated without pumped medium (
n
Avoid cavitation:
–
Open the inlet side valve fully during pump operation and do not use for
regulating the pump capacity.
–
Open the outlet side valve fully during pump operation.
n
Never operate the pump against a closed or partially closed valve in the
outlet line.
n
Avoid motor damage:
–
Observe permissible number of motor switch-on instances per hour (
manufacturer's instructions).
n
Only use the pump if it is in a technically optimal condition and ensure it is
operated in accordance with the regulations and in a safety and risk-aware
manner under observance of this manual.
n
Any other use must be agreed with the ITT Bornemann GmbH.
n
Observe the operational limits of the pump in relation to temperature, pres-
sure, viscosity, pump capacity and speed (
pump data sheet).
n
When pumping liquids containing solids comply with the limit values for the
proportion of solids and grain size (
pump data sheet).
n
When pumping liquids containing gas comply with the limit values for the pro-
portion of gas (
pump data sheet).
n
Incorporate suitable safety valves (pressure safety valves are not system
safety valves).
n
Do not use the pump without a pressure safety valve or similar safeguard
against exceeding the differential pressure.
n
Do not use the pressure safety valve for regulating the pump capacity or
pressure.
n
Do not operate the pump without a check valve.
n
Connect the inlet and outlet lines correctly in accordance with the direction of
flow (see connection labelling).
n
Check the installation direction of the check valve.
n
Implement and check the connection labelling for the inlet and outlet lines.
2.2 Improper use
Any use other than uses detailed under
Chapter 2.1 ‘Intended use’ on page 10
shall be considered improper and is impermissible, for example:
Safety
Type SLH-4G, SLHS-4G
10
01/2016 JPB Rev. 5