Section 7, Plumbing the System
International Thermal Research
7-5
Figure 7-3: Three Approved Methods of Installing Heater Hose
(consult ITR for alternative methods and products)
7.4 Potable Water Plumbing Installation
The Potable water connections are located on top of the Hurricane
®
Zephyr. The Cold-Water Inlet and Hot-Water Outlet are be connected
using PEX crimp fittings.
Both connections for Potable Cold Inlet and Potable Hot Outlet
(labeled as such) are made with a crimped, Pex to Pex connection.
The maximum water supply pressure to the heater is 150 PSI (10
bar). The Hot water outlet temperature is regulated by an internal
mixing valve factory set at 120F (49°C). If needed this valve can be
adjusted between a range of 75F (24°C) to a maximum of 145F
(63°C). See Figure 7-4: Potable Hot water system plumbing.
ITR warranty does not cover damage caused by leaks from
connections made during installation.
All fittings, hose, tube and fitting sealant involving the potable water
must be food safe and approved for use with potable water and rated
for the potable water system pressure.
NOTICE
WARNING
Содержание Hurricane Zephyr HW
Страница 14: ...Section 1 Overview 1 8 Installation Manual for Hurricane Zephyr HW Heating System...
Страница 20: ...Section 2 Mounting the Heater Unit 2 6 Installation Manual for Hurricane Zephyr HW Heating...
Страница 28: ...Section 4 Installing the Fuel System 4 4 Installation Manual for Hurricane Zephyr HW Heating System...
Страница 34: ...Section 5 Installing Fan Heaters 5 6 Installation Manual for Hurricane Zephyr HW Heating System...
Страница 43: ...Section 6 Wiring the Electrical System International Thermal Research 6 9...
Страница 83: ...Section 11 Maintenance 11 6 Installation Manual for Hurricane Zephyr HW Heating System...
Страница 88: ...International Thermal Research Warranty Information International Thermal Research Page 5...
Страница 89: ...Warranty Information International Thermal Research Page 6 International Thermal Research...