Section 6, Wiring the Electrical System
International Thermal Research
6-7
2
Wire the positive terminal of the house battery through a
25-amp, heavy-duty rated fuse (using #10-gauge wire) to
the positive terminal on the control board inside the main
control box. Wire the negative terminal of the house
battery to the negative terminal of the control board. Wire
the heater ground wire directly to battery negative.
3
Using the recommended wire gauges, prepare all wire
terminations for approved connections from the control
board to each of the fan heaters and thermostats (and any
optional switches).
4
Wire the fan heaters to the terminals in the control board
using #16 wire (minimum) and a #8 fork connection on
each fan. There are four terminals, F1 to F4,
corresponding to the four zones. See Figure 6-4.
5
Connect the fan grounds to the negative terminal of the
battery or to an adjacent chassis ground location.
6
Wire the thermostats for the fan heaters to the terminals
in the control board using #18-gauge wire (minimum) and
a single #8 fork connection. See Figure 6-4 for the correct
terminals (T1 to T4, and T-C common).
7
If domestic water heating, engine waste heat, or
summer/winter loop functions of the heater are required.
See Sections 9 and 10 for details.
8
If installing any optional fan speed switches, wire them to
the RV’s wiring system, not to the heater control board.
Install the switch between the fan circuit and the positive
DC fan connection using #16 wire (minimum) and a #8
fork connection. See Figure 6-2 switch wiring diagram.
9
Mount the TouchScreen remote panel in the living areas
where it can be easily accessed. Any accessory switches
should be mounted adjacent to the remote panel for ease
of use.
10 Connect the RJ11 remote cable from the control board to
the remote panel.
11 Ensure that all pre-wired connections between the heater
and control box are secure.
Содержание Hurricane Zephyr HW
Страница 14: ...Section 1 Overview 1 8 Installation Manual for Hurricane Zephyr HW Heating System...
Страница 20: ...Section 2 Mounting the Heater Unit 2 6 Installation Manual for Hurricane Zephyr HW Heating...
Страница 28: ...Section 4 Installing the Fuel System 4 4 Installation Manual for Hurricane Zephyr HW Heating System...
Страница 34: ...Section 5 Installing Fan Heaters 5 6 Installation Manual for Hurricane Zephyr HW Heating System...
Страница 43: ...Section 6 Wiring the Electrical System International Thermal Research 6 9...
Страница 83: ...Section 11 Maintenance 11 6 Installation Manual for Hurricane Zephyr HW Heating System...
Страница 88: ...International Thermal Research Warranty Information International Thermal Research Page 5...
Страница 89: ...Warranty Information International Thermal Research Page 6 International Thermal Research...