Original notice - A1.20
F-RAT-NX75 Technical document
76
Transfer capacity
Appendix
Appendix 4.
Transfer capacity
Safety precautions
Advance preparation
Product check
Structures
Installation/Wiring
Control/Operation
Maintenance/Inspection
Tr
oubleshooting
Appendix
Transfer time
Receiving time
(sec)
Transfer surface
exchange cycle time (sec)
Discharge time
(sec)
Transfer time
+
+
=
2
3
3
3
4
Package length (mm)
(Transfer speed* (m/min) /60) x 1000
One cycle time = 1,10 sec
Cycle time to exchange
the transfer surface
and then return to start position
i.e. wheels
ĺ
rollers
ĺ
wheels (sec)
Discharge time (graph 1) +
additional time depending on the
weight of the package (table1)
From reception of the
package until the next
package is ready
to be transferred on the
F-RAT-N75, after the
package has been fully
discharged.
60 (m/min)
30 (m/min)
20 (m/min)
3
2.5
2
1.5
1
0.5
0
250
300
350
400
450
500
550
600
650
700
Package size (mm)
Graph 1
Discharge time (sec)
Package weight (kg)
10
20
30
40
50
Additional time (sec)
0.1
0.2
0.3
0,4
0,5
Table 1
Note : Transfer time may vary according to the load, its transfer method (step by step, continuous), upstream and downstream
conveyor speed and other factors.
* Average speed between package
in-feed and outfeed