Original notice - A1.20
24
F-RAT-NX75 Technical document
Safety precautions
Advance preparation
Product check
Structures
Installation/Wiring
Control/Operation
Maintenance/Inspection
Tr
oubleshooting
Appendix
・
Prepare stands, and perform frame processing in advance by reference to the mounting
holes in dimensions.
・
Determine the mounting location for zone sensors to check the existence of trays, and
area sensors to check loading and discharging. Then, prepare for them to be mounted.
7-1.
Before installation
Mounting preparation for
the F-RAT main unit
Size 6040
L
595mm×W395mm
Size 6050
L595mm×W495mm
7.
Installation/Wiring
*Guide for cable marginal projecting length
(mm)
M1 : Carrier wheel transfer MDR
M2 : Roller transfer MDR
M3 : Drive switching MDR
1000
1100
1300
*Guide for cable marginal projecting length
(mm)
M1 : Carrier wheel transfer MDR
M2 : Roller transfer MDR
M3 : Drive switching MDR
1000
1000
1300
Size
6040・6050
Cable
*
Cable
*
125
(T
ransfer surface)
595
495
470
(Mounting hole position)
12.5
550
(Mounting nut position)
22.5
75
75
75
75
75
75
17
542
(Pipe size)
95
80
70
80
70
80
22.5
44
22.5
22.5
Excluding projection
595
550
(Mounting nut position)
395
22.5
75
75
75
75
17
542
(Pipe size)
125
(T
ransfer surface)
95
47.5
47.5
12.5
370
(Mounting hole position)
70
80
80
22.5
44
45
45
4 × Mounting nut(M8)
Excluding projection
Min and max size load
・
Minimum load size : 225 x 225mm
・
Maximum load size : -100mm from the length and the width of F-RAT-NX75.