Original notice - A1.20
48
:
Factory setting
Speed chart
8-3.
Changing the speed
〔
M1:CBK-109 / M2:CB-016
〕
Changing the speed
■
Values in “Setting” indicate the speed when trays are not placed on carrier
wheels and rollers.
■
During operation, the rising time to the setting speed may vary depending on
ambient temperature. Perform running operation thoroughly.
■
Values described above may differ from the actual transfer speed depending on
the weight, material, bottom surface, and/or shape of trays, as well as ambient
temperature.
SW1#5
:
ON
(
m/min
)
SW5
61.5
8
56.4
7
53.9
6
51.3
5
48.7
4
46.2
3
41.1
2
38.4
1
35.9
0
0
33.4
SW1#5
:
OFF
9
30.8
8
28.2
7
25.6
6
23.1
5
20.5
4
18.0
3
15.5
2
12.8
1
10.3 7.7
59.8 56.4 53.9 51.3 48.7 46.2 41.1 38.4 35.9 33.4 30.8 28.2 25.6 23.1 20.5 18.0 15.5 12.8 10.3 7.7
Speed accuracy:
±
3%
Speed accuracy:
±
3%
Setting
Rated
Setting
Rated
[
M1
:
Carrier wheel speed
]
[
M2
:
Roller speed
]
External voltage
Input
(V)
External voltage
Input
(V)
〜
9.6
9.9
〜
9.1
9.4
〜
8.6
8.9
〜
8.1
8.4
〜
7.6
7.9
〜
7.1
7.4
〜
6.6
6.9
〜
6.1
6.4
〜
5.6
5.9
〜
5.1
5.4
〜
4.6
4.9
〜
4.1
4.4
〜
3.6
3.9
〜
3.1
3.4
〜
2.6
2.9
〜
2.1
2.4
〜
1.6
1.9
〜
1.1
1.4
〜
0.6
0.9
〜
0.1
0.4
:
Factory setting
SW1#5
:
ON
SW5
8
7
6
5
4
3
2
1
0
0
SW1#5
:
OFF
9
8
7
6
5
4
3
2
1
53.5 53.5 53.5 51.4 48.9 46.3 41.2 38.6 36.0 33.4 30.9 28.3 25.7 23.1 20.6 18.0 15.4 12.9 10.3 7.7
61.7 56.6 54.0 51.4 48.9 46.3 41.2 38.6 36.0 33.4 30.9 28.3 25.7 23.1 20.6 18.0 15.4 12.9 10.3 7.7
Nominal speed
60 m/min
type
〜
9.6
9.9
〜
9.1
9.4
〜
8.6
8.9
〜
8.1
8.4
〜
7.6
7.9
〜
7.1
7.4
〜
6.6
6.9
〜
6.1
6.4
〜
5.6
5.9
〜
5.1
5.4
〜
4.6
4.9
〜
4.1
4.4
〜
3.6
3.9
〜
3.1
3.4
〜
2.6
2.9
〜
2.1
2.4
〜
1.6
1.9
〜
1.1
1.4
〜
0.6
0.9
〜
0.1
0.4
9
9
8.
Control/Operation
F-RAT-NX75 Technical document
Safety precautions
Advance preparation
Product check
Structures
Installation/Wiring
Control/Operation
Maintenance/Inspection
Tr
oubleshooting
Appendix