Appendix D: System Planning Worksheets
48
F33
Downloader Access
Enable
On enables, off disables remote downloader station programming.
(Same as option 88 in User-Programming menu.)
OFF
F35
Telephone Panics
On enables, off disables phone button panics and upper sensors 80,
81, and 82 are not generated from the telephone.
OFF
F36
On-Premise Telephone
Control
On enables, off disables on-premise phone control of panel.
ON
F37
Quick Arming
On enables, off disables touchpad quick-arming commands.
ON
F40
Smoke Verification
On = if a hardwire smoke sensor trips, the panel resets all hardwire
smoke sensors and waits for a second trip (within 5 minutes) before
alarm is generated. An alarm is also generated if the panel doesn’t
receive a restoral after the first trip.
Off = panel only requires one trip.
OFF
F41
Interior Siren Verifica-
tion
On = panel monitors interior siren wiring for shorts/opens.
OFF
F42
Source Reporting
On = panel reports source of alarm (which touchpad/device) to the
central station when S77 and S80-87 reports are sent.
ON
F43
Demo Kit Mode
On enables, off disables special demo kit mode of operation.
OFF
F44
Constant Exterior Siren On = exterior siren relay output latches and remains latched for intru-
sion alarms, for siren timeout duration or until alarm is canceled.
OFF = exterior siren relay output modulates between open and
closed states for normal intrusion alarm output.
OFF
F45
Keyswitch Control
(Arming/Disarming)
On = allows zone 1 to arm and disarm the system, using a keyswitch
or dry relay contact output of an access system connected to a panel
hardwire input, HIM, or door/window sensor terminals.
Off = no keyswitch arming/disarming
OFF
F46
Daylight Savings Time
On automatically adjusts the panel clock at 2:00am on the first Sun-
day in April for daylight-savings time and the last Sunday in October
for standard time. These changes are logged in the event buffer.
ON
F47
4-Hour Trouble Timer
On = group 26 (fire) sensors reporting a low battery, tamper, pre-
alarm, or trouble condition cause the system to sound trouble beeps.
Pressing STATUS or changing arming level stops trouble beeps for 4
hours. Trouble beeps sound again in 4 hours if problem is not fixed.
Must be on for UL Listed installations.
Off = group 26 sensors initiate trouble beeps immediately or within
10-hours (as per F21 setting).
ON