Programming the Panel
9
Adding (Learning) Wireless
Sensors
Programming wireless and hardwire sensors involves
switching the panel to the program mode of operation
and setting sensor identification numbers and group
numbers for each wireless sensor and hardwire sensor
loop. Once sensors IDs and group assignments are
added (learned) into panel memory, the panel can re-
spond appropriately for each sensor detection. Sen-
sors can be added (learned) into or deleted from panel
memory.
Use table C.1 in appendix C for selecting sensor
groups and complete the group assignment for each
wireless sensor in the system planning worksheets in
appendix D.
Use the following procedure to add (learn) all Learn
Mode wireless sensors.
To add Learn Mode wireless sensors into panel
memory:
1. In PROGRAM MODE, press the touchpad
BYPASS or STATUS button repeatedly until
LEARN SENSOR is displayed.
2. Press the COMMAND button to display
GROUP __ __.
3. Enter the desired group number (00 to 29, 32).
4. Press the COMMAND button to display SEN-
SOR ##.
5. Press the COMMAND button if the sensor num-
ber displayed is OK or enter another number
from 01 to 76, and then press COMMAND
again.
6. The display reads TRIP - ##. Trip the wireless
sensor tamper switch as shown in table 2 or as
described in the sensor’s installation instructions.
When the sensor has been added (learned) the
display reads TRIP - ## [next #] and interior
speakers announce Sensor # okay. Sensor [next #
to be learned].
Note
To trip a wireless sensor with an external hard-wire contact
connected to its screw terminals, check that the external
contact is in its alarm state, and then trip the sensor.
The alarm state is either open or closed, depending on the
normal condition of the sensor. Multiple normally closed
switches are wired in series and tripped while the loop is
open. Multiple normally open switches are wired in parallel
and tripped while the loop is closed.
For high-security installations, always remove both internal
reed switches when connecting an external contact to the
wireless sensor terminals.
Only the normally closed configuration can be used in UL-
listed installations.
Do not attempt to use the built-in reed switch
and an exter-
nal contact on the same wireless sensor.
7. Continue adding sensors into the current group
number by repeating step 6 for each sensor. Press
BYPASS, STATUS, or number buttons to select
new sensor numbers (other than what is automat-
ically displayed).
8. To add sensors into other groups, press FIRE
and follow steps 3 through 7.
Table 2 Tripping Learn Mode Wireless
Sensors
Sensor *
Action
Door/Window
†
Open sensor cover.
Fire Pull Station
Open t h e sensor cover located
insid e the Fire Pull Station.
Freeze
Open sensor cover.
Glass Guard
Open sensor cover.
Portable Emergency But-
tons
Pres s the appropriate emer-
gency button(s).
PIR Motion
Open PIR case.
Keychain Touchpad
Simultaneously press arm and dis-
arm until the LED flashes.
Rate-of-Rise Heat
Open sensor cover and press learn
switch on circuit board.
Recessed Door/Window
Open sensor cover and remove
transmitte r circuit board.
Shock
†
Open sensor cover.
Slim Line Door/Window
Remove sensor f ro m mounting
base.
Sound
Open sound sensor cover, after
spring is installed.
System Sensor Smoke
System Sensor 2300RF ITI
Pres s tes t button and hold for
30 seconds, until tes t alarm
begins sounding.
Wit h sensor removed from base,
press the test button for at least
1 second.
*
Refer to the particular sensor’s installation instructions for
more details on tripping Learn Mode wireless sensors.
†
When using an external contact with this sensor, the contact
must be in the alarm state while tripping the sensor to properly
learn it into memory.