Appendix D: System Planning Worksheets
46
Table D.8 Upper Sensor Numbers
No.
Sensor Name
Description
Default Setting
77
Touchpad Tamper
Reports a touchpad tamper to the Central Station (CS) if 40 digits are
entered without a valid access code.
OFF
78
Freeze Sensor
On will activate and report a Freeze Alarm when the room temperature
reaches the programmed freeze temperature. When on, and no tempera-
ture data is received from the Energy Saver Module (ESM), a 78 TROUBLE
alarm is reported.
OFF
79
No Activity
When on, if no activity is detected on the premises within the programmed
Activity Time-out, the auxiliary siren will sound. The panel reports to the CS
if the alarm is not canceled within 5 minutes.
OFF
80
Touchpad Fire
Panic
On enables the FIRE button on all touchpads (and telephones if F35 is on).
ON
81
Touchpad Police
Panic
ON enables the POLICE button on all touchpads (and telephones if F35 is
on).
ON
82
Touchpad Auxiliary
Panic
On enables the AUXILIARY button on all touchpads (and telephones if F35
is on).
ON
83
Manual Phone
Test
Allows the user to instruct the system to dial CS and report a phone test.
ON
84
Opening Report
Reports to the CS when the user disarms the system.
OFF
85
Closing Report
Reports to the CS when the user arms the system.
OFF
86
Duress Alarm
Reports a silent POLICE EMERGENCY to the CS.
OFF
87
Force Armed
Reports a FORCE ARMED when user directly or indirectly bypasses any
sensor. Security level and bypassed sensor are reported. (Auto Force
Armed is always reported.)
OFF
88
Energy Saver
Enable
When on, the Energy Saver Module (ESM) is able to override the con-
nected thermostat. When on and no temperature data is received from the
ESM, an 88 TROUBLE alarm is reported.
OFF
89
Wireless Touch-
pad Supervisory
or Low Battery
When on, the panel checks for and reports supervisory conditions on Wall
Mount Wireless touchpads. Reports a SUPERVISORY alarm to the alpha-
numeric touchpad if the panel doesn't hear from each touchpad within the
set time (SUPSYNC). If on, the panel will report a touchpad low battery
when any touchpad has a low battery condition.
OFF
90
AC Power Failure
If on, reports an AC FAILURE to the CS if the panel has been without AC
power for 15 minutes.
OFF
91
Low Panel Battery If on, reports LOW CPU BATTERY to the CS if the panel's back-up battery
voltage drops below 11.4 VDC.
ON
92
Panel Tamper
If on and armed to level 2 or 3, changing from run to program will activate
and report a CPU TAMPER alarm.
ON
93
Automatic Phone
Test
If on, the panel reports to the CS at a programmed interval (from daily to
every 255 days).
OFF
94
Receiver Failure
If on, the panel reports to the CS if the panel does not hear from any wire-
less transmitter for 2 hours. Trouble beeps alert user of the problem.
ON
95
Panel Back In
Service
When on, the panel reports to the CS at power-up and if a panel reset
occurs.
ON
96
Phone Failure
If the panel is unsuccessful reporting to the CS after the third of eight
attempts, the panel activates a FAIL TO COMMUNICATE alarm. It contin-
ues to dial the remaining five attempts.
ON
98
Events Report
If on (and panel is set up for ITI phone format), the panel automatically
reports to the CS when 28 events are accumulated in the event buffer. If off,
the panel doesn’t report but still accumulates events in the buffer.
Note: Must be off if panel is set up for 4/2 Phone Format.
OFF