Appendix C: Programming Tables
37
Appendix C: Programming Tables
This appendix contains tables for selecting sensor group numbers and X-10 Lamp and Appliance Module house
and unit codes. Table notes appear at the bottom of the table, on the next page.
Table C.1 Sensor Group Characteristics
No.
Name
Application
Alarm
Delay
Restoral
Supervisory
CS
Report
Chime
Active
Levels
00
Fixed
Panic
24-hour audible fixed emergency but-
tons.
Police
Instant
√
√
1, 2, 3
01
Portable
Panic
24-hour audible portable emergency
buttons.
Police
Instant
√
1, 2, 3
02
Fixed
Panic
24-hour silent fixed emergency buttons.
Silent
Instant
√
√
1, 2, 3
03
Portable
Panic
24-hour silent portable emergency but-
tons.
Silent
Instant
√
1, 2, 3
04
Fixed
Auxiliary
24-hour auxiliary sensor, such as Pen-
dant Panic or holdup button.
Auxiliary
Instant
√
√
1, 2, 3
05
Fixed
Auxiliary
24-hour auxiliary emergency button.
Siren shutoff confirms CS report.
Auxiliary
Instant
√
√
1, 2, 3
06
Portable
Auxiliary
24-hour portable auxiliary alert button.
Auxiliary
Instant
√
1, 2, 3
07
Portable
Auxiliary
24-hour portable auxiliary button. Siren
shutoff confirms CS report.
Auxiliary
Instant
√
1, 2, 3
08
Special
Intrusion
Special belongings, such as gun cabi-
nets and wall safes.
Police
Instant
√
√
√
1, 2, 3
09
Special
Intrusion
Special belongings, such as gun cabi-
nets and wall safes.
Police
Standard
√
√
√
1, 2, 3
10
Entry/Exit
Delay
Entry and exit doors that require a stan-
dard delay time.
Police
Standard
√
√
√
√
2, 3
11
Entry/Exit
Delay
Garage doors and entrances that
require an extended delay time.
*
Police
Extended
√
√
√
√
2, 3
12
Entry/Exit
Delay
Driveway gates and entrances that
require a twice extended delay time.
*
Police
Twice
Extended
√
√
√
√
2, 3
13
Instant
Perimeter
Exterior doors and windows.
Police
Instant
√
√
√
√
2, 3
14
Instant
Interior
Interior doors.
Police
Follower
√
√
√
2, 3
15
Instant
Interior
Interior PIR motion sensors.
*
Police
Follower
√
√
2, 3
16
Instant
Interior
Interior doors.
Police
Follower
√
√
√
3
17
Instant
Interior
PIR motion sensors.
*
Police
Follower
√
√
3
18
Instant
Interior
PIR motion sensors subject to false
alarms.
*
†
Police
Follower
√
√
3
(continued)
19
Delayed
Interior
Interior doors that initiate a delay before
going into alarm.
*
Police
Standard
√
√
√
3
Содержание ITI UltraGard