Installing Line Carrier Devices
22
•
3 OFF, 4 ON—The WIS internal piezos and
external siren produce high-volume status tones.
Use this setting when status tones need to be
heard in remote areas, inside and outside of the
premises.
Caution
Never turn on both DIP switches 3 and 4; doing so may per-
manently damage the WIS.
3. Connect the battery to the battery clip and insert
the battery into the compartment.
4. Replace the battery cover.
Connecting an External Siren
to the WIS
Figure 7 shows how to connect the Hardwire Exterior
Siren (13-046) to the WIS terminals. These terminals
activate for alarms only and provide 100 mA maxi-
mum current at 6 VDC.
Caution
Only the Hardwire Exterior Siren (13-046) can be connected
to the WIS terminals. Other sirens may draw more current
than the WIS can provide and can cause permanent dam-
age to the WIS.
Figure 7 Wiring the Hardwire Exterior Siren to the
WIS
Programming the WIS House
Code
1. Plug the WIS into an outlet that is not controlled
by a switch.
2. Press CODE + 1 on the alphanumeric touchpad.
3. The WIS sounds one beep and the WIS LED
flashes, indicating the WIS received the signal
from the panel.
Note
If WIS DIP switches 3 and 4 are set to OFF, no beep will be
heard. You must cause an alarm for the WIS to sound.
4. If the WIS does not respond, unplug it and dis-
connect the battery. Wait at least 30 seconds, and
then reconnect the battery and repeat steps 1 and
2. If the WIS still does not respond, proceed to
appendix B, “Troubleshooting.”
5. To permanently mount the WIS, unplug it and
remove the outlet cover screw.
6. Plug the WIS into the outlet and secure it with
the outlet screw.
WARNING!
Use extreme caution when securing the WIS to a metal
outlet cover. You could receive a serious shock if the
metal outlet cover drops down onto the prongs of the
plug while you are securing the WIS and cover to the
outlet box.
Installing X-10 Lamp Modules
When installing X-10 Lamp Modules:
• Use only incandescent lamps.
• Do not plug X-10 Lamp Modules into outlets con-
trolled by a switch.
• Do not use extension cords to connect several
lamps to one module.
Caution
Use X-10
Lamp Modules to control light fixtures. Do not use
X-10
Appliance Modules. Appliance Modules are not con-
trolled during an alarm.
OBSERVE
POLARITY
BATTERY
COMPARTMENT
(DIP SWITCHES
INSIDE)
HARDWIRE EXTERIOR SIREN (13-046)
100 mA MAXIMUM DRAW
+
8557G23A.DS4
Содержание ITI UltraGard