Voltage Measurement Commands
Copyright © Itech Electronic Co., Ltd.
22
device setting values and will not trigger the measurement operation.It only
requires to get the latest value that has been measured.
Command Syntax
FETCh:[:SCALar]:VOLTage:MN?
Returned value
<NR2>
MEASure[:SCALar]:VOLTage:MN?
This command is used to read real-time MN(Calibration to the average rectified
value of the effective value) of voltage.
Command Syntax
MEASure[:SCALar]:VOLTage:MN?
Returned value
<NR2>
FETCh[:SCALar]:VOLTage:CFACtor?
This command is used to read the latest pre-processing voltage crest factor.It
will not affect the device setting values and will not trigger a new measurement
operation.It only requires to get the latest available value that has been
measured.
Command Syntax
FETCh[:SCALar]:VOLTage:CFACtor?
Returned value
<NR2>
MEASure[:SCALar]:VOLTage:CFACtor?
This command will trigger the measurement operation to get a real-time voltage
crest factor.
Command Syntax
MEASure[:SCALar]:VOLTage:CFACtor?
Returned value
<NR2>
FETCh[:SCALar]:VOLTage:MAXPk?
This command is used to read the latest pre-processing positive peak voltage.It
will not affect the device setting values and will not trigger a new measurement
operation.It only requires to get the latest available value that has been
measured.