Voltage Measurement Commands
Copyright © Itech Electronic Co., Ltd.
23
Command syntax
FETCh[:SCALar]:VOLTage:MAXPk?
Returned value
<NR2>
MEASure[:SCALar]:VOLTage:MAXPk?
This command will trigger the measurement operation to get a real-time positive
peak voltage.
Command Syntax
MEASure[:SCALar]:VOLTage:MAXPk?
Returned value
<NR2>
FETCh[:SCALar]:VOLTage:MINPk?
This command is used to read the latest pre-processing negative peak
voltage.It will not affect the device setting values and will not trigger a new
measurement operation.It only requires to get the latest available value that has
been measured.
Command Syntax
FETCh[:SCALar]:VOLTage:MINPk?
Returned value
<NR2>
MEASure[:SCALar]:VOLTage:MINPk?
This command will trigger the measurement operation to get a real-time
negative peak voltage.
Command Syntax
MEASure[:SCALar]:VOLTage:MINPk?
Returned value
<NR2>
FETCh[:SCALar]:VOLTage:PPEak?
This command is used to read the latest pre-processing peak-peak voltage.It
will not affect the device setting values and will not trigger a new measurement
operation.It only requires to get the latest available value that has been
measured.
Command Syntax
FETCh[:SCALar]:VOLTage:PPEak?