Harmonic Measurement Commands
Copyright © Itech Electronic Co., Ltd.
43
FETCh[:SCALar]:HARMonics:POWer:PHASe:UI?
This command is used to read the latest pre-processing phase difference of
K-order harmonic voltage(Uk) and harmonic current.It will not affect the device
setting values and will not trigger a new measurement operation.It only requires
to get the latest available value that has been measured.
Command Syntax
FETCh[:SCALar]:HARMonics:POWer:PHASe:UI?
Parameters
NR1(0-50)
Returned value
<NRf>
MEASure[:SCALar]:HARMonics:POWer:PHASe:UI?
This command will trigger the measurement operation to get a real-time phase
difference of K-order harmonic voltage(Uk) and harmonic current.
Command Syntax
MEASure[:SCALar]:HARMonics:POWer:PHASe:UI?
Parameters
NR1(0-50)
Returned value
<NRf>
FETCh[:SCALar]:HARMonics:POWer:PHASe:II?
This command is used to read the latest pre-processing phase difference of
K-order harmonic current(Ik) and fundamental wave(I1).It will not affect the
device setting values and will not trigger a new measurement operation.It only
requires to get the latest available value that has been measured.
Command Syntax
FETCh[:SCALar]:HARMonics:POWer:PHASe:II?
Parameters
NR1(0-50)
Returned value
<NRf>
MEASure[:SCALar]:HARMonics:POWer:PHASe:II?
This command will trigger the measurement operation to get a real-time phase
difference of K-order harmonic current(Ik) and fundamental wave(I1).