Function
and Features
Copyright ©ITECH Electronic Co., Ltd.
21
You can press the keys on the front panel of the electronic load to edit the
sequence operation files, and trigger this sequence operation. Or you may
directly recall existing sequence operation files to trigger the sequence
operation.For example, when the DUT output voltage is 10V and the output
current is 3A, after editing the sequence operation files under Constant Current
(CC) mode, the steps for triggering sequence operation are as follows:
Operation steps
1. Press
[Shift]
+ 3 keys.
LIST
On Recall Edit
2. Operate
key and move to Edit. Press
[Enter]
key.
EDIT LIST
High-Rate Low-Rate
3. Operate
key and move to the High-Rate and press
[Enter]
key.
EDIT LIST
Current Range=3A
4. Edit number of steps. Press 2 key to edit two steps. Press
[Enter]
key.
EDIT LIST
File Step=2
(
2-84
)
5. Edit current value in step 1 and press
[Enter]
key.
EDIT LIST
Step 001 Level=1A
6. Edit slope in step 1 and press
[Enter]
key.
EDIT LIST
Step 001 Rate=0.1A/uS
7. Edit time in step 1 and press
[Enter]
key.
EDIT LIST
Step 001 Width=5S
8. Edit current value in step 2 and press
[Enter]
key.
EDIT LIST
Step 002 Level=2A
9. Edit slope in step 2 and press
[Enter]
key.
EDIT LIST
Step 002 Rate=0.1A/uS
10. Edit time in step 2 and press
[Enter]
key.
EDIT LIST
Step 002 Width=5S
11. Edit repeat count and press
[Enter]
key.
Trigger
1
0
2
3 4
5
List count=1
List count=2
List sequence