32
Safety Instructions Prior To Installation/Pilot Assembly Wire Diagram
ISOFLAMES
FIREPLACE WIDTH
FIREPLACE HEIGHT BTU NATURAL GAS
BTU LIQUID
BURNER
MINIMUM
PROPANE
24”
IBV 36”
30”
50,000
50,000
30”
IBV 46”
30”
65,000
65,000
8. Gas supply pressures:
GAS
SUPPLY
PRESSURE NATURAL
GAS
LIQUID
PROPANE
Minimum inlet gas supply pressure for the purpose of input adjustment
5” w.c.
10.5” w.c.
Maximum inlet gas supply pressure
7” w.c.
13” w.c.
Manifold pressure
3.5” w.c. 10” w.c.
The ISOFLAMES gas log system’s gas control valve must be disconnected from gas supply piping system during any pressure
testing of the ISOFLAMES gas log system at test pressures in excess of 1/2 psi (3.5kpa). The ISOFLAMES gas log system must
be isolated from the gas piping system by closing the gas control valve during any pressure testing of the gas supply piping system
at test pressures less than 1/2 psi (3.5kPa).
9. All ISOFLAME gas log assembly systems (whether with Safety Pilot Valve or Remote Pilot Valve) are equipped with a 1/8 NPT
plugged tapping, accessible for test gage connection, immediately upstream of the gas supply connection to the appliance.
10. The ISOFLAMES gas logs are convertible if done by a certified gas technician.
11. Keep the ISOFLAMES gas log system’s area clear and free from combustible materials such as gasoline and other flammable
vapors and liquids.
12. Do not use the ISOFLAMES gas log system if any part has been immersed in water. Call a qualified service technician to
inspect the ISOFLAMES gas log system. Replace any part of the ISOFLAMES gas log system that has been immersed in water.
13. The fireplace chimney and flue needs to be inspected and cleaned once a year by a qualified service technician.