28
SAFETY
BASIC PRINCIPLES
USE
MAINTENANCE
F18
F19
1
2
Emptying the condensate tray
F18
The blast chiller is equipped with a special tray to
collect condensation and washing water, located in the
lower part of the cabinet. Periodically empty and clean the
bowl, pulling it out from under the cabinet.
Cleaning and replacing the filter
F19
The filter must be cleaned every 20 hours or weekly,
also based on the working conditions of the machine
(if the environment is very dusty, such as with flour or similar,
cleaning will be more frequent). To access the filter it is
necessary to open the door and pull the front grille towards
you with a slight force. Clean the filter by blowing it with
compressed air, alternatively wash it with hot water and a
neutral detergent or replace it. After cleaning, when closing
the grille, make sure that the plastic pins lock into the
appropriate spaces. Do not operate the machine without a
filter or with a filter that is not perfectly dry.
Cleaning the seal
Periodically check the condition and tightness of the door
seal; if it is damaged, contact an authorized dealer or service
centre for replacement.
Clean it with a cloth soaked in warm soapy water.
Finish with rinsing and drying with the door open with a
manual defrost cycle.
Weekly cleaning
At the same time also clean the plastic of the seal to ensure
perfect adherence.