TABLE OF CONTENTS
Page i
BP+15-150,2.9X
5/95
Section I
Theory of Operation
1.1
General ............................................................................................... Page 1.1
1.2
Rectifier/Charger ......................................................................................... 1.1
1.3
Inverter........................................................................................................ 1.2
1.4
Static Bypass Switch....................................................................................1.2
1.5
Batteries ...................................................................................................... 1.2
1.6
Control Logic and Control Circuitry ............................................................ 1.3
1.7
Digital Monitoring Panel.............................................................................. 1.3
1.8
Multi-Level Passwords ................................................................................ 1.4
1.9
Phone Home Alarm Reporting ..................................................................... 1.5
1.10
Dial-Back Security...................................................................................... 1.5
Section II
Installation
2.1 General................................................................................................... Page 2.1
2.2 Mechanical Preparation of UPS .......................................................................2.1
Figure 2-1 Casters and Leveling Feet..................................................................2.3
2.3 Mechanical Preparation of the Battery Cabinet(s) ............................................2.4
2.4 Signal Wiring ..................................................................................................2.5
2.4.1 Remote Control (TB 1) ...........................................................................2.5
2.4.2 Optional Remote Status Panel (TB2).......................................................2.6
2.4.3 Optional RS232 Communication (J6-J9) ................................................. 2.6
2.4.4 Optional Modem Connection (J10-J13)...................................................2.6
2.4.5 Optional Site Interface Assembly (A26).................................................. 2.7
2.4.6 Optional User Specified Alarm (A33) ..................................................... 2.7
2.5 Power Wiring
-
UPS to Battery Cabinet........................................................... 2.7
2.6 Connecting the Cabinets .................................................................................. 2.8
Figure 2.2 Bolting Battery Cabinet to UPS ......................................................... 2.8
2.7 Re-assembly .................................................................................................... 2.8
2.8 AC Power Connection ..................................................................................... 2.9
2.9 Activating the Battery Cabinet(s)..................................................................... 2.11
2.9.1 Battery Cabinet #1 ................................................................................... 2.12
2.9.2 Battery Cabinet #2 ................................................................................... 2.13
2.9.3 Battery Cabinets #3 and #4 ...................................................................... 2.14
2.9.4 Final Battery Cabinet Connections ........................................................... 2.14
Figure 2-3 Battery Interconnections .................................................................... 2.15
Installation Drawings