Section 2:
Configuration
Revision 1.0a
30
© 2006 Intuicom, Inc.
Figure 2-15: Multipoint Subnet Diagram
Transceiver
Rcv
SubnetID
Xmit
SubnetID
Notes
Master
NA
NA
May be set to anything
Repeater1
0
1
0 forces it to link only to the Master
Repeater2 1 2
Rcv SubnetID=1 forces communication
through Repeater1 (Repeater1 transmits
on SubnetID 1)
Slave1 0
NA
Rcv SubnetID=0 forces communication
through the Master
Slave2 1
NA
Rcv SubnetID=1 forces communication
through Repeater1
Slave3 2
NA
Rcv SubnetID=2 forces communication
through Repeater2
Slave4 F
F
Setting of FF allows the Slave to link with
the first Master or Repeater it hears with
the correct NetworkID
Table 2-6: Subnet ID Settings for example Multipoint Subnet Diagram
Note: If you set the Rcv Subnet ID to '0', the modem (other than a master) will
communicate only with a master. If you set both Subnet IDs to 'FF', the modem will
communicate with any other modem in the same sub-network. Other than that, you can
set any value for these settings.