RRP: Power Supply
Use the following procedures to remove or replace a power supply. A
list of tools required is provided.
Tools Required
The following tools are required to perform these procedures.
•
Door key with 5/16-inch socket (provided with the FC-512
Fabricenter equipment cabinet).
•
Standard flat-tip screwdriver.
•
ESD grounding cable and wrist strap.
Removal
To remove a power supply:
1. If the director is installed in a stand-alone configuration, go to
step 2
. If the director is rack-mounted, perform one of the
following:
— If the director is installed in a McDATA-supplied FC-512
Fabricenter equipment cabinet, insert the 5/16" door tool into
the socket hole at the right top of the rear door. Turn the tool
counter-clockwise to unlock and open the door.
— If the director is installed in a customer-supplied equipment
cabinet, unlock and open the cabinet rear door as directed by
the customer representative.
ATTENTION!
To avoid causing machine errors or damage while working on
the director, follow ESD procedures by connecting a grounding cable to the
director chassis and wearing an ESD wrist strap.
2. Follow ESD procedures by attaching a wrist strap to the director
chassis and your wrist (
Figure 5-1
).
3. Identify the defective power supply from the extinguished green
PWR OK
LED on the supply or failure information at the
management server Hardware View.
4. Use a flat-tip screwdriver to release the handle at the top of the
power supply.
Содержание Intrepid 6140 Director
Страница 4: ...Intrepid 6140 Director Installation and Service Manual iv ...
Страница 14: ...xiv Intrepid 6140 Director Installation and Service Manual Figures ...
Страница 42: ...1 1 20 Intrepid 6140 Director Installation and Service Manual General Information ...
Страница 120: ...2 2 78 Intrepid 6140 Director Installation and Service Manual Installation Tasks ...
Страница 282: ...5 5 46 Intrepid 6140 Director Installation and Service Manual Removal and Replacement Procedures RRPs ...
Страница 294: ...6 6 12 Intrepid 6140 Director Installation and Service Manual Illustrated Parts Breakdown ...
Страница 366: ...A A 72 Intrepid 6140 Director Installation and Service Manual Event Code Tables ...
Страница 370: ...B B 4 Intrepid 6140 Director Installation and Service Manual Director Specifications ...
Страница 374: ...C C 4 Intrepid 6140 Director Installation and Service Manual Management Server and Ethernet Hub ...
Страница 382: ...D D 8 Intrepid 6140 Director Installation and Service Manual Restore Management Server ...
Страница 385: ...E E 3 Safety Notices Multi Lingual Translations ...
Страница 390: ...E E 8 Intrepid 6140 Director Installation and Service Manual Safety Notices Multi Lingual Translations ...