40
If it does not stop then disconnect power to the stove and plug in
fan direct.
If it still cycles then it is a bad fan and must be replaced.
If it does not cycle when plugged in direct then change the board.
TROUBLE SHOOTING DURING THE RUN CYCLE:
*THE QUALITY OF PELLETS YOU USE WILL DIRECTLY INFLUENCE THE
PERFORMANCE OF YOUR STOVE.
*PELLET STOVES ARE NOT MEANT TO RUN ON HIGH FOR LONG
PERIODS OF TIME, THE HIGH LEVELS ARE ONLY MEANT TO INITIALLY
BRING THE ROOM UP TO A DESIRED HEAT.
*YOU MUST CLEAN OUT YOUR PELLET STOVE REGULARLY IN ORDER
FOR IT TO PERFORM EFFECTIVELY.
*ALL TESTING OF THE STOVE IN THIS SECTION SHOULD BE
PERFORMED AFTER THE START UP CYCLE AND DURING THE RUN
CYCLE.
The stove is smoking into the house:
If you have a power failure or an exhaust fan failure and you do
not have a fresh air intake hooked up then you may get smoke in
the house.
If both the intake and exhaust are installed and you are still getting
smoke in the house then you will want to check that your exhaust
is hooked up properly to code and that it is
COMPLETELY
SEALED (this is very important, this is the main cause of most
smoke issues).
Check to make sure your intake is going to the outside and is
sealed properly.
If problem persists then get a new board with the extended shut
down cycle on it and the exhaust fan will stay on for 10 minutes
after shut down to ensure everything is exhausted out.
High limit switch keeps tripping:
As we stated above no pellet stove is designed to run on high for
long periods of time. It is like running your car; you would never
drive it all out peddle to the metal everywhere you go, it is not
designed for that. The same thing with your pellet stove, use the
high levels to bring the room up to heat and then turn the stove
down.
The convection fan has a fail safe at 210 degrees Fahrenheit; it will
shut down if it gets that hot. If the convection fan shuts down then
the stove heats up to an unsafe temperature and the high limit trips.
That is what it is supposed to do. The pellets will stop feeding and
the stove will shut down and flash level 3.